Anticonvulsants in serum, determined with a fully mechanized enzyme analyzer.
نویسندگان
چکیده
The "EMIT" enzyme immunoassay system (Syva) that involves use of glucose-6-phosphate dehydrogenase (EC 1.1.1.49) as the enzyme label has been adapted to a fully mechanized kinetic enzyme analyzer for analysis of phenobarbital, phenytoin, and primidone. This procedure, compared with the gas-chromatographic procedure of Kupferberg [Clin. Chim. Acta 29, 283 (1970)], gave a weighted regression line--forced through the origin--of y=(1.01+/-0.04) x for phenobarbital, y=(0.95+/-0.04) x for primidone. Within-run coefficients of variation based on single determinations were 9,11, and 22% for primidone, phenobarbital, and phenytoin, respectively. Run-to-run assay CV was 6% for primidone and phenobarbital and 13% for phenytoin, based on the means of triplicate determinations of a sample with a mid-range concentration.
منابع مشابه
Determination of methotrexate in serum by a rapid, fully mechanized enzyme immunoassay (EMIT).
A homogeneous enzyme immunoassay for the determination of methotrexate in serum (EMIT, Syva Corp.) was fully mechanized by the use of an Eppendorf analyzer 5010. Coefficients of variation from day to day were in the range 2--16%. A comparison of the results obtained by EMIT and a radioimmunoassay (Methotrexate 125 I Radioimmunoassay Kit, Diagnostic Biochemistry Inc.) in a series of 50 samples f...
متن کاملEvaluation of homogeneous enzyme immunoassay of serum thyroxine with the Gilford 3500 analyzer.
I evaluated homogeneous enzyme immunoassay (EMIT) of serum thyroxine with the Gilford 3500 analyzer. The samples are pretreated before quantitation on the Gilford 3500; the procedure thereafter is entirely mechanized. Forty-four samples may be analyzed per run. Precision and accuracy are good, and results correlate well with those by radioimmunoassay.
متن کاملA simple, kinetic procedure for the optimized determination of the activity of serum glutamate dehydrogenase (EC 1.4.1.2.) with an enzyme analyzer.
The reliability of a mechanized procedure for the determination of the glutamate dehydrogenase activity in human sera was investigated with an Eppendorf analyzer 5011. In spite of a 1:3.5 ratio of sample to assay volume, carry-over effects can be neglected between sera containing less than 60 U/l. For routine purposes it is suggested that 0.3 U/l be subtracted from each activity found in human ...
متن کاملEvaluation of automated enzyme immunoassays for five anticonvulsants and theophylline adapted to a centrifugal analyzer.
We report a clinical evaluation of the enzyme immunoassay (EMIT) performed with the GEMSAEC centrifugal analyzer as compared to gas-liquid and liquid chromatography for anticonvulsant drugs and theophylline, respectively. A good correlation was obtained for all drugs, although some difficulties were experienced with one lot of reagent for ethosuximide. The analyzer has an economic advantage if ...
متن کاملAdaptation of "EMIT" technique for serum phenobarbital and diphenylhydantoin assays to the miniature centrifugal analyzer.
We used a miniature centrifugal analyzer in a spectrophotometric rate-measurement mode to determine the anticonvulsant drugs phenobarbital and diphenylhydantoin in serum, by use of a modified enzyme immunoassay ("EMIT", Syva Corp.) We decreased reagent cost per determination by at least sixfold by means of microscale techniques. Also, the analysis rate is increased by measuring multiple samples...