Occlusion effect of earmolds with different venting systems.

نویسندگان

  • Jürgen Kiessling
  • Barbara Brenner
  • Charlotte Thunberg Jespersen
  • Jennifer Groth
  • Ole Dyrlund Jensen
چکیده

In this study the occlusion effect was quantified for five types of earmolds with different venting. Nine normal-hearing listeners and ten experienced hearing aid users were provided with conventional earmolds with 1.6 and 2.4 mm circular venting, shell type earmolds with a novel vent design with equivalent cross-sectional vent areas, and nonoccluding soft silicone eartips of a commercial hearing instrument. For all venting systems, the occlusion effect was measured using a probe microphone system and subjectively rated in test and retest sessions. The results for both normal-hearing subjects and hearing aid users showed that the novel vents caused significantly less occlusion than the traditional vents. Occlusion effect associated with the soft silicone eartip was comparable to the nonoccluded ear. Test-retest reproducibility was higher for the subjective occlusion rating than for the objectively measured occlusion. Perceived occlusion revealed a closer relationship to measured occlusion in the ear in which the measured occlusion effect was higher ("high OE" ear) than in the "low OE" ear. As our results suggest that subjective judgment of occlusion is directly related to the acoustic mass of the air column in the vent, the amount of perceived occlusion may be predicted by the vent dimensions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Maximum usable real-ear insertion gain with ten earmold designs.

The present study compared the maximum usable real-ear insertion gain (REIG) permitted by 10 earmold designs that varied in the amount of occlusion. These earmolds were coupled to a high-gain hearing aid (Phonak Super-Front PPCL). In addition, the specificity of a nonoccluding earmold for the Oticon E43 hearing aid was examined. Maximum usable REIG, defined as the insertion gain obtained with t...

متن کامل

The effects of venting and low-frequency gain compensation on performance in noise with directional hearing instruments.

The present study investigated the effects of gain compensation and venting on front-to-back ratios (FBRs), speech understanding in noise, and acceptance of noise in 19 listeners with hearing impairment utilizing directional hearing instruments. The participants were separated into two groups based on degree of low-frequency hearing sensitivity. Subjects were fitted binaurally with Starkey Axen...

متن کامل

The occlusion effect in unilateral versus bilateral hearing aids.

The benefit of bilateral hearing aids is well documented, but many hearing-aid users still wear only one aid. It is plausible that the occlusion effect is part of the reason for some hearing-aid users not wearing both hearing aids. In this study we quantified the subjective occlusion effect by asking ten experienced users of bilateral hearing aids and a reference group of ten normal-hearing ind...

متن کامل

Left ventricular unloading during reperfusion does not limit myocardial infarct size.

To determine whether venting the left ventricle during coronary reperfusion limits myocardial infarct size, we studied paced (200 beats/min) Langendorff rabbit hearts, perfused with blood from a support rabbit. A left coronary artery was occluded for 60 minutes, followed by 2 hours of reperfusion. Four experimental conditions, as follows, were used: In group 1 (control), the hearts contracted i...

متن کامل

Comparison of vent effects between a solid earmold and a hollow earmold.

BACKGROUND Hollow earmolds have become a popular type of earmold used in thin-tube, microsize hearing aid fittings. It is desirable for clinicians to be familiar with their characteristics and limitations. PURPOSE This investigation compared the effects of vent diameter between a traditional solid earmold and a hollow earmold that is used in modern thin-tube hearing aid fittings. RESEARCH D...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Academy of Audiology

دوره 16 4  شماره 

صفحات  -

تاریخ انتشار 2005