Title: Breathing motion compensated reconstruction for C-arm cone beam CT imaging: initial experience based on animal data

نویسندگان

  • D. Schäfer
  • M. Lin
  • P. P. Rao
  • R. Loffroy
  • E. Liapi
  • N. Noordhoek
  • P. Eshuis
  • A. Radaelli
  • M. Grass
  • J.-F.H. Geschwind
چکیده

C-arm based tomographic 3D imaging is applied in an increasing number of minimal invasive procedures. Due to the limited acquisition speed for a complete projection data set required for tomographic reconstruction, breathing motion is a potential source of artifacts. This is the case for patients who cannot comply breathing commands (e.g. due to anesthesia). Intra-scan motion estimation and compensation is required. Here, a scheme for projection based local breathing motion estimation is combined with an anatomy adapted interpolation strategy and subsequent motion compensated filtered back projection. The breathing motion vector is measured as a displacement vector on the projections of a tomographic short scan acquisition using the diaphragm as a landmark. Scaling of the displacement to the acquisition iso-center and anatomy adapted volumetric motion vector field interpolation delivers a 3D motion vector field per voxel. Motion compensated filtered back projection incorporates this motion vector field in the image reconstruction process. This approach is applied in animal experiments on a flat panel C-arm system delivering improved image quality (lower artifact levels, improved tumor delineation) in 3D liver tumor imaging. Purpose: C-arm based tomographic 3D imaging is applied in an increasing number of minimal invasive procedures [1]. Next to 3D rotational angiographic imaging, new acquisition, detection and reconstruction strategies enable CT like low contrast 3D imaging at high spatial resolution in interventional radiology [2]. Due to the limited acquisition speed of a projection data set sufficient for tomographic reconstruction, breathing motion is a potential source of artifacts in interventional applications. Typical rotational acquisition protocols have durations of 5-20 sec. This results in excellent image quality for patients with breath hold. In case of less healthy patients which can not comply or patients under anesthesia motion artifacts can occur. Intra-scan motion estimation and compensation is required. In the following, a scheme for projection based local breathing motion estimation is combined with an anatomy adapted interpolation strategy and subsequent motion compensated filtered back projection. This approach is applied in animal experiments on a flat panel based C-arm system to improve the image quality in 3D liver tumor imaging. Here, rabbits with an implanted VX-2 liver tumor model are imaged for translational liver cancer research utilizing an imaging system also used in human interventional oncology applications. Methods: Since short scan rotational X-ray acquisitions do not contain redundant cone-beam data, projection based motion estimation must be used to determine the breathing motion pattern. As an indicator for the breathing motion the diaphragm region is selected. When using a circular short scan for the projection acquisition, the location of this region of interest (ROI) remains in a relatively fixed area on the projection during the rotational run. This ROI is selected, gradient filtered (see Fig. 1), and integrated along the projection of the tangential of the source trajectory on the detector plane (see Fig. 2). Fig. 1: Original projection of the rabbit model (left image) and two selected region of interest projections (middle and right column) before and after gradient filtering (upper and lower image). The diaphragm motion is estimated by cross-correlation analysis of the filtered and integrated ROIs and a caudo-cranial shift vector is derived [3]. Subsequently, the ribcage and diaphragm are semiautomatically segmented from a standard 3D filtered back projection cone-beam reconstruction [4] using Sobel filtered volume data and a manual seed point segmentation. A 3D motion vector field (MVF) is interpolated for every voxel by keeping the ribcage static and applying the detected motion to the diaphragm using distance weighted scattered data interpolation from three nearest neighbour points of the MVF [5]. The motion-compensated cone beam filtered back projection reconstruction is obtained by applying the motion vector during back-projection [6]. Fig. 2: Filtered ROI projection with the integration direction indicated by red arrows (left image). 2D images with each column representing the filtered and integrate ROI of one projection without (upper right image) and with (lower right image) a line indicating the diaphragm motion. Results: Projection data have been acquired at John’s Hopkins University, Baltimore, USA using a commercial C-arm system (Allura XperFD20, Philips Healthcare, Best, The Netherlands) with a low contrast XperCT protocol for translational interventional research with the VX2 rabbit liver tumor model. Small physical size and rapid cardio-ventilatory motion in the rabbit poses a challenge in producing adequate imaging. Three different acquisition protocols have been used to acquire the data: A – 20 sec scan time, 30 fps acquisition speed, 5 msec pulse length; B – 10 sec, 30 fps, 5 msec; C – 5 sec, 60 fps, 5 msec. Images have been reconstructed using cone beam filtered back projection with and without motion compensation. The image quality was assessed based on image contrast, artifacts, and tumor delineation. For the standard reconstruction the image quality improved with decreasing scan time. For all protocols the motion compensation improved the image quality with respect to image contrast, artifact level and tumor delineation (one example given in Fig. 3). Conclusions: Motion compensation of the rabbit ventilation resulted in improved IQ and can enable use of clinical C-arm systems for pre-clinical imaging to facilitate translational imaging research. Potential transfer of this technique to human applications requires further evaluation. New or breakthrough work presented: Sharp tumor delineation is possible with intra-scan breathing motion compensation. Fig. 3: Comparison of the image quality for an animal scan with a standard reconstruction (left column) and a motion compensated reconstruction (right column). Reconstruction has been performed with 1mm voxel size from 308 projections acquired in 5 sec (L: 150 / W: 500 HU).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Image artefact propagation in motion estimation and reconstruction in interventional cardiac C-arm CT.

The acquisition of data for cardiac imaging using a C-arm computed tomography system requires several seconds and multiple heartbeats. Hence, incorporation of motion correction in the reconstruction step may improve the resulting image quality. Cardiac motion can be estimated by deformable three-dimensional (3D)/3D registration performed on initial 3D images of different heart phases. This moti...

متن کامل

Motion-Compensated Cone Beam CT Using a Conjugate Gradient Least Squares Algorithm and EIT Imaging Motion Data

Cone Beam Computed Tomography (CBCT) is an imaging modality that has been used in image-guided radiation therapy (IGRT). For applications such as lung radiation therapy, CBCT images are greatly affected by the motion artefacts. This is mainly due to low temporal resolution of CBCT. Recently, a dual modality of Electrical Impedance Tomography (EIT) and CBCT has been proposed, in which the high t...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Improving iterative 4D CBCT through the use of motion information

In Image-Guided RadioTherapy (IGRT) of lung tumors, patients undergo a 4D CT, on the basis of which their treatment is planned. It is implicitely assumed that their breathing motion will not change much throughout the treatment, and remain close to what it was during the 4D CT acquisition. During the treatment, several cone beam CT acquisitions are performed, and used to re-position the patient...

متن کامل

Image-based compensation for involuntary motion in weight-bearing C-arm cone-beam CT scanning of knees

We previously introduced four fiducial marker-based strategies to compensate for involuntary knee-joint motion during weight-bearing C-arm CT scanning of the lower body. 2D methods showed significant reduction of motionrelated artifacts, but 3D methods worked best. However, previous methods led to increased examination times and patient discomfort caused by the marker attachment process. Moreov...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011