Performance of transport ventilator with patient-triggered ventilation.

نویسندگان

  • E Miyoshi
  • Y Fujino
  • T Mashimo
  • M Nishimura
چکیده

OBJECTIVES Transport ventilators with inspiratory triggering functions and pressure support-control modes have recently become commercially available. We evaluated these ventilators in comparison with a standard ICU ventilator. STUDY DESIGN Laboratory study with a mechanical lung model. METHODS We compared the performance of four transport ventilators (model 740, Mallinckrodt, Pleasanton, CA; TBird, Bird Products Corp, Palm Springs, CA; LTV1000, Pulmonetic Systems, Colton, CA; Esprit, Respironics, Vista, CA) with a standard ICU ventilator (model 7200ae; Mallinckrodt) using a test lung that simulated spontaneous breathing (compliance, 46.8 mL/cm H(2)O; resistance, 5 cm H(2)O/L/s). The settings of ventilators were positive end-expiratory pressure (PEEP) of 0 or 5 cm H(2)O, and pressure support (PS) of 0 or 10 cm H(2)O. The settings of the test lung were inspiratory time of 1 s, respiratory rate of 10/min, peak inspiratory flow of 40, 60, and 80 L/min. To evaluate inspiratory function at each setting, we measured the inspiratory delay time (DT), inspiratory trigger pressure (P-I), and the time for airway pressure to rise from the baseline pressure to 90% of the end-inspiratory pressure (T(90%)); for expiratory function, supraplateau expiratory pressure (P-E) and the time constant (taue) for pressure decrease during exhalation were evaluated. Oxygen requirement was assessed as the time required to empty a 3.5-L oxygen tank. RESULTS For inspiratory triggering, four transport ventilators had DT < 100 ms, which is considered clinically satisfactory, in all the settings except for PS 0 cm H(2)O, PEEP 0 cm H(2)O, and inspiratory flow of 80 L/min with LTV1000. P-I increased only in LTV1000 when PEEP was increased from 0 to 5 cm H(2)O. taue for the transport ventilators was > 50% shorter than for the ICU ventilator except for PS 0 cm H(2)O and PEEP 5 cm H(2)O with TBird. Oxygen requirement was lowest for the Esprit, followed by the 740, LTV1000, and TBird. CONCLUSION The newer Food and Drug Administration-approved transport ventilators have performance indexes comparable to the ventilator currently used in ICUs and can probably be recommended for clinical use.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patient triggered ventilation using a flow triggered system.

The role of patient triggered ventilation (PTV) for the newborn was assessed using a new patient triggered ventilator, the Draeger Bablylog 8000, which incorporates significant improvements in both ventilator performance and the triggering system. Thirty three infants, median gestational age 30 weeks and postnatal age 2.5 days, were entered into the study to compare blood gases obtained during ...

متن کامل

Respiratory support using patient triggered ventilation in the neonatal period.

There are now a number of purpose built patient triggered ventilators for use in the newborn. These ventilators are triggered either by air flow or airway pressure changes, their triggering devices all have very high sensitivity and short systems delay. They all have the advantage that they perform well without inadvertent positive end expiratory pressure at the fast ventilator rates frequently...

متن کامل

Neonatal patient triggered ventilation.

Patient triggered ventilation was assessed in 14 neonates (gestational age 24-40 weeks). Inspiratory changes in airflow, monitored by a pneumotachograph, were used to trigger the ventilator and this was not associated with complications. Patient triggered ventilation was maintained for up to eight hours (mean duration five hours). In 13 of 14 infants oxygenation improved and this was associated...

متن کامل

Tilt Table Practice Improved Ventilation in a Patient with Prolonged Artificial Ventilation Support in Intensive Care Unit

Patients who are on prolonged ventilator support in critical care unit present wide variety of complications, which range from reduction in oxygen uptake to various musculoskeletal impair-ments. Early mobilization and rehabilitation are encouraged to manage these complications effectively. Use of tilt table to motivate early mobilization in the intensive care unit for ventilator practices is no...

متن کامل

Comparison of triggering systems for neonatal patient triggered ventilation.

The efficacy of two triggering systems was compared during neonatal patient triggered ventilation: the Graseby MR10 respiration monitor and airway pressure changes. Ten preterm infants were studied, median gestational age 33 weeks (range 28-35). Patient triggered ventilation was administered via the SLE ventilator at a series of inflation times (0.24, 0.3, and 0.4 seconds). Comparison was made ...

متن کامل

Randomised controlled trial of patient triggered and conventional fast rate ventilation in neonatal respiratory distress syndrome.

AIM To compare patient triggered, with conventional fast rate, ventilation in a randomised controlled trial using the incidence of chronic lung disease as the primary outcome measure. METHODS Three hundred and eighty six preterm infants with birthweights from 1000 to 2000 g, and requiring ventilation for respiratory distress syndrome within 24 hours of birth, were randomised to receive either...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chest

دوره 118 4  شماره 

صفحات  -

تاریخ انتشار 2000