An Emc Market Surveillance Project on Energy-saving Lamps in Finland
نویسنده
چکیده
The Safety Technology Authority (TUKES) organized EMC market surveillance tests on 36 energy-saving lamp models, according to the standard EN 55015. First of all, conducted disturbance emissions at mains ports were tested for. The first test results showed that 10 lamps out of 36 did not pass the tests and that there were serious defects in three lamp types. Surprisingly, defects were found to be equally distributed between inexpensive and expensive lamp models. Following this, 10 lamps were selected to undergo a magnetic disturbance test, but none failed. As well as this, the harmonic current emissions caused by energy-saving lamps are going to be tested in the near future. In the product family standard for electrical lighting and similar equipment (EN 55015), there are no measuring methods available for testing radiated emissions. However, we intended to make radiated interference tests on some energy-saving lamps, according to the standard EN 55022. Our aim was to analyze the radiated interference levels of energy-saving lamps and to compare these with the interference levels permitted for other electrical products. Also, four halogen floor lamps were tested and analyzed as a point of comparison.
منابع مشابه
An EMC Market Surveillance Project for Frequency Converters in Finland
Three EMC market surveillance projects have been carried out in Finland. The first project was for uninterruptible power systems, the second was for personal computers and the latest one has been for frequency converters. The project required the Finnish frequency converter market be monitored and manufacturers and importers identified. Much documentation was requested and thoroughly checked. A...
متن کاملFinnish Safety and EMC Market Surveillance Statistics
In Finland, electrical safety and EMC market surveillance activities have been collected together in the TUVA database, which contains information on over 10,000 cases. In this paper, the TUVA database is statistically analyzed. The aim of this paper is to ascertain whether there is a potential use and usefulness for the application of these statistics when evaluating the effectiveness of the F...
متن کاملCorrelations between the Interference Statistics of Finnish Radio Systems and EMC Market Surveillance In Finland
In this paper two sets of interference statistics have been compared against those of the EMC market surveillance statistics made by The Safety Technology Authority (TUKES). The main focus has been on electrical equipment. The aim of the paper is to find out whether there is a potential use and usefulness for the applying of interference statistics when evaluating the effectiveness of EMC marke...
متن کاملLight Spectrum of Compact Fluorescent Lamps in Iranian Market and Possibility of Hydroxyl Radical Production
Background and purpose: Despite growing use of energy-saving lamps or compact fluorescent lamps (CFLs), there are concerns about ultraviolet radiation in their output. In this study, the output of CFLs available in Iranian market in the range of infrared, visible, and ultraviolet were measured and the possibility of hydroxyl radical production by their radiation was evaluated. Materials and me...
متن کاملارزیابی میدانهای الکتریکی و مغناطیسی لامپهای کم مصرف از نوع فلورسنت فشرده از دیدگاه حفاظت پرتوی
The technology used in energy-saving compact fluorescent lamps (CFLs), provides a quarter of the energy consumption of incandescent lamps to produce equivalent light energy while CLFs shelf life is up to ten times of incandescent lamps. So the incandescent lamps in homes and workplaces are replaced with CFLs. Due to the use of ballast in the structure of CFLs, electric and magnetic fields are g...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2003