Individualised pulse oximetry limits in neonatal intensive care.

نویسندگان

  • R Gupta
  • C W Yoxall
  • N Subhedar
  • N J Shaw
چکیده

AIM To determine whether individualised limits for arterial oxyhaemaglobin saturation by pulse oximetry (SpO(2)) are more effective for detecting hypoxia and hyperoxia in sick newborn infants than setting fixed limits. METHODS Six hundred and ninety two simultaneous measurements of SpO(2) and partial pressure of oxygen in arterial blood (PaO(2)) were made in 95 infants. The sensitivity and specificity for predicting hypoxia and hyperoxia using various fixed SpO(2) limits and also individualised SpO(2) limits, calculated using a standard equation, were determined and compared. RESULTS None of the fixed limits for SpO(2) was both sensitive and specific for predicting hypoxia and/or hyperoxia. There was no difference between these and individualised limits. CONCLUSION Individualised SpO(2) limits are no more effective than fixed SpO(2) limits for predicting hypoxia and/or hyperoxia in sick newborn infants. SpO(2) monitoring is not an ideal method for assessing PaO(2).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessing the Performance of Nurses in the Proper Adjustment of Monitoring Instruments in the Neonatal Intensive Care Unit

Background: Monitoring serves to maintain physiologic variables within normal limits and when a parameter crosses a set threshold, an alarm is triggered. Therefore, this study aimed to determine whether alarm limits are properly adjusted in the neonatal intensive care unit (NICU) by nursing staff or not.Methods: The data concerning alarm limits corresponding to the three shifts of nursing...

متن کامل

Introducing random safety audits (RSA) in a neonatal intensive care unit (NICU).

Random safety audits (RSA) have been shown to be effective in improving standards of clinical practice. 19 data collection audits were performed relating to hygiene, safe prescribing, oxygen pulse oximetry monitoring and documentation in keeping with the requirements of the new Medical Practitioners Act (MPA) 2007. Hygiene audits (range from 20/25 to 21/21 80%-100%) and safe prescribing audits ...

متن کامل

Accuracy of pulse oximetry in assessing heart rate of infants in the neonatal intensive care unit.

AIM To determine the accuracy of pulse oximetry measurement of heart rate in the neonatal intensive care unit. METHODS Stable preterm infants were monitored with a pulse oximeter and an ECG. The displays of both monitors were captured on video. Heart rate data from both monitors, including measures of signal quality, were extracted and analysed using Bland Altman plots. RESULTS In 30 infant...

متن کامل

Pulse Oximetry Screening to Detect Cyanotic Congenital Heart Disease in Sick Neonates in a Neonatal Intensive Care Unit.

OBJECTIVE To evaluate pulse oximetry for detection of congenital cyanotic heart disease in sick neonates using echocardiography as gold standard. METHODS Pulse oximetry readings were taken at admission from 950 neonates from right upper limb and either foot with infant breathing room air. Pulse oximetry was considered abnormal if oxygen saturation at room air measured <90% or difference betwe...

متن کامل

Early dynamic changes in pulse oximetry signals in preterm newborns with histologic chorioamnionitis.

OBJECTIVE No reliable clinical markers of histologic chorioamnionitis (HCA), a major and often subclinical cause of prematurity leading to high neonatal morbidity and mortality, are available to date. Increasing evidence indicates myocardial dysfunctions in affected fetuses and newborns. We sought to assess the value of nonlinear dynamics from pulse oximetry signals in identifying affected newb...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archives of disease in childhood. Fetal and neonatal edition

دوره 83 1  شماره 

صفحات  -

تاریخ انتشار 1999