Simultaneous determination of asenapine and valproic acid in human plasma using LC–MS/MS: Application of the method to support pharmacokinetic study

نویسندگان

  • Ambavaram Vijaya Bhaskar Reddy
  • Nandigam Venugopal
  • Gajulapalle Madhavi
چکیده

Combination of asenapine with valproic acid received regulatory approval for acute treatment of schizophrenia and maniac episodes of bipolar disorders. A simple LC-MS/MS method was developed and validated for simultaneous quantification of asenapine and valproic acid in human plasma. Internal standards were added to 300 μL of plasma sample prior to liquid-liquid extraction using methyl tertiary butyl ether (MTBE). Chromatographic separation was achieved on Phenomenex C18 column (50 mm×4.6 mm, 5 μm) in isocratic mode at 40 °C. The mobile phase used was 10 mM ammonium formate-acetonitrile (5:95, v/v) at a constant flow rate of 0.8 mL/min monitored on triple quadrupole mass spectrometer, operating in the multiple reaction monitoring (MRM) mode. The injection volume used for LC-MS/MS analysis was 15 μL and the run time was 2.5 min. These low run time and small injection volume suggest the high efficiency of the proposed method. The method was validated over the concentration range of 0.1-10.02 ng/mL and 10-20,000 ng/mL for asenapine and valproic acid respectively. The method recoveries of asenapine (81.33%), valproic acid (81.70%), gliclazide (78.45%) and benzoic acid (79.73) from spiked plasma samples were consistent and reproducible. The application of this method was demonstrated by a pharmacokinetic study in 8 healthy male volunteers with 5 mg asenapine and 250 mg valproic acid administration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A quick and Sensitive Liquid Chromatography–tandem Mass Spectrometry (LC-MS) Method for the Determination of Enalapril and Enalaprilat in Human Plasma: Application to a Bioequivalence Study

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method for the estimation of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode was operated under the multiple-reaction monitoring mode. Sample pretreatment involved in a one-step protein precipitat...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

Development and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry

The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...

متن کامل

Method validation of methotrexate in human plasma by LC-MS technique in patients with brain tumor.

Background and aims: A selective and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been established for determination of methotrexate in human plasma. Methods: Methotrexate was extracted from plasma with acetonitrile. The mobile phase consisted of acetonitrile-water-formic acid 74: 25: 1(v/v). Twenty...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2013