Determination method for mono- and diethanolamine in workplace air by high-performance liquid chromatography.

نویسندگان

  • Akito Takeuchi
  • Takashi Kitade
  • Akira Jukurogi
  • Warren Hendricks
  • Yuichiro Kaifuku
  • Kenji Shibayama
  • Shuichiro Natsumeda
  • Hirokazu Ota
  • Shu Yamada
  • Kimiaki Sumino
  • Akira Namera
  • Seiichiro Kanno
چکیده

OBJECTIVES The purpose of this research was to develop a simultaneous determination method for monoethanol-amine (MEA) and diethanolamine (DEA) in workplace air for risk assessment. METHODS The characteristics of the proposed method, such as recovery, quantitation limit, reproducibility and storage stability of the samples, were examined. RESULTS An air sampling cassette containing two sulfuric acid-treated glass fiber filters was chosen as the sampler. The MEA and DEA were extracted from the sampler filters, derivatized with 9-fluorenylmethyloxycarbonyl chloride and then analyzed by a high-performance liquid Chromatograph equipped with a fluorescence detector or photo-diode array detector. The overall recoveries from spiked samplers were 86-99 and 88-99% for MEA and DEA, respectively. The recovery after 5 days of storage in a refrigerator exceeded 95%. The overall limits of quantitation were 0.750 and 0.100 jug/sample for MEA and DEA, respectively. The relative standard deviations, which represent the overall reproducibility defined as precision, were 0.3-1.6 and 0.4-5.7% for MEA and DEA, respectively. CONCLUSIONS The proposed method enables 4-h personal exposure monitoring of MEA and DEA at concentrations equaling 1/3,000-2 times the threshold limit value-time-weighted average (TLV-TWA: 3 ppmfor MEA, 1 mg/m(3) for DEA) adopted by the American Conference of Governmental Industrial Hygienists and also by the Japan Society for Occupational Health. The method is useful for estimating worker exposure to MEA and DEA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Determination of Four Preservatives in Foodstuffs by High Performance Liquid Chromatography

Background and objectives:  High concentration of preservatives in food may result in gastrointestinal disturbances whereby some patients suffering from asthma, rhinitis, or urticaria. The aim of this study is the introduction and optimization a new method for simultaneous determination of four preservatives (SB, PS, MP, PP) in foodstuff by high performance liquid chromatography. Materi...

متن کامل

Determination of some B Vitamins in Sour Cherry Juice Using Dispersive Liquid-liquid Microextraction Followed by High-performance Liquid Chromatography

Dispersive liquid-liquid microextraction method (DLLME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine thiamine (B1), nicotinamide (B3) and pyridoxine (B6) in sour cherry juice. This method was rapid, simple and sensitive. Separation was accomplished using a C18 column. The optimum chromatographic conditions were found to be: mobile ph...

متن کامل

Trace Determination of Duloxetine in Human Plasma by a Novel Ionic Liquid-Based Ultrasound-Assisted In Situ Solvent Formation Microextraction and High-Performance Liquid Chromatography

For the first time, a novel and efficient ionic liquid-based ultrasound-assisted in-situ solvent formation microextraction (IL-UA-ISFME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) has been successfully developed for the determination of duloxetine (DLX) in human plasma. Herein, an environmentally-friendly hydrophobic ionic liquid (1-butyl-3-methylimidaz...

متن کامل

Ionic Liquid-based Ultrasound-assisted In-situ Solvent Formation Microextraction and High-performance Liquid Chromatography for the Trace Determination of Polycyclic Aromatic Hydrocarbons in Environmental Water Samples

A green and efficient ionic liquid-based ultrasound-assisted in-situ solvent formationmicroextraction (IL-UA-ISFME) in combination with high-performance liquid chromatographyultravioletdetection (HPLC-UV) has been successfully developed for the trace determination offive selected polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. In thismethod, a hydrophobic ionic liquid (1...

متن کامل

Determination of Aflatoxins B1 and B2 in Powdered Milk Using Modified Liquid Chromatography Method

Background & Aims: In this study, using a liquid-liquid microextraction method for pre-concentration trace amounts of aflatoxins, the amount of Aflatoxins B1 and B2 in powdered milk was determined. Determination of aflatoxins was done by using high-performance liquid chromatography coupled with fluorescent detector. Method: Samples were extracted by immunoaffinity column (IAC) clean-up, and the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of occupational health

دوره 54 4  شماره 

صفحات  -

تاریخ انتشار 2012