Shot-noise-limited Doppler-broadened noise-immune cavity-enhanced optical heterodyne molecular spectrometry.

نویسندگان

  • Gang Zhao
  • Thomas Hausmaninger
  • Weiguang Ma
  • Ove Axner
چکیده

Shot-noise-limited Doppler-broadened (Db) noise-immune cavity-enhanced optical heterodyne molecular spectrometry (NICE-OHMS) has been realized by implementation of balanced detection. A characterization of the system based on Allan-Werle plots of the absorption coefficient, retrieved by fitting a model function to data, shows that the system has a white noise equivalent absorption per unit length per square root of bandwidth of 2.3×10-13  cm-1 Hz-1/2, solely 44% above the shot noise limit, and a detection sensitivity of 2.2×10-14  cm-1 over 200 s, both being unprecedented for Db NICE-OHMS. The white noise response follows the expected inverse square root dependence on power that is representative of a shot-noise-limited response, which confirms that the system is shot-noise-limited.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Broadly tunable mid-infrared noise-immune cavity-enhanced optical heterodyne molecular spectrometer.

The sensitive spectroscopic technique noise-immune cavity-enhanced optical heterodyne molecular spectroscopy (NICE-OHMS) has been successfully used in a variety of systems; however, no broadly tunable setup has been developed for the mid-infrared. To this end, we have integrated a difference frequency generation system into a NICE-OHMS setup. Initial optimization and characterization was comple...

متن کامل

Characterization of an external cavity diode laser based ring cavity NICE-OHMS system.

The performance of an external cavity diode laser based noise immune cavity enhanced optical heterodyne molecular spectrometer is presented. To reduce the noise on the signal a ring cavity and a circuit to remove residual amplitude modulation on the pre-cavity laser radiation was implemented. We demonstrate a sensitivity of 4 x 10(-11) cm(-1) Hz(-1/2) using a cavity with a finesse of 2600 on a ...

متن کامل

External cavity diode laser-based detection of trace gases with NICE-OHMS using current modulation.

We combine an external cavity diode laser with noise-immune cavity-enhanced optical heterodyne molecular spectroscopy (NICE-OHMS) using current modulation. With a finesse of 1600, we demonstrate noise equivalent absorption sensitivities of 4.1 x 10(-10) cm(-1) Hz(-1/2), resulting in sub-ppbv detection limits for Doppler-broadened transitions of CH(4) at 6132.3 cm(-1), C(2)H(2) at 6578.5 cm(-1) ...

متن کامل

Molecular Ion Spectroscopy : New Methods and the Proposed Study of H 2 CO +

The novel technique of cavity enhanced velocity modulationspectroscopy has recently been demonstrated as the first general absorptiontechnique that allows for sub-Doppler spectroscopy of molecular ionswhile retaining ion-neutral discrimination. The previous experimentalsetup has been further improved with the addition of heterodyne detectionin a NICE-OHMS setup. This improve...

متن کامل

Optical heterodyne detection in cavity ring-down spectroscopy

Polarization-selective optical heterodyne detection is shown to enhance the practical sensitivity of cavity ring-down spectroscopy. Initial experiments demonstrate a signal-to-noise ratio above 31 dB. Minor improvements should yield shot-noise-limited operation. q 1998. Published by Elsevier Science B.V. All rights reserved.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics letters

دوره 43 4  شماره 

صفحات  -

تاریخ انتشار 2018