Do unloading periods affect migration characteristics of cemented femoral components? An in vitro evaluation with the Exeter stem.

نویسندگان

  • N Verdonschot
  • M Barink
  • J Stolk
  • J W M Gardeniers
  • B W Schreurs
چکیده

Prosthetic migration has been identified as a marker for future revision of cemented total hip reconstructions. This could be tested at a pre-clinical stage with dynamic loading experiments. The purpose of this study was to assess the effects of resting periods, which are a considerable part of the daily activity cycle, on the migration characteristics of femoral cemented stems. Ten polished Exeter stems were implanted in composite femurs and loaded either with a continuous load or a discontinuous load. Continuous loading involved 345,600 loading cycles at 1 Hz, whereas the discontinuous loading involved loading at 1 Hz for 2.5 hours and a resting period of 21.5 hours for a period of four days. Hence, a total of 36,000 loading cycles were applied to these reconstructions. The subsidence patterns of the prostheses were considerably affected by the resting periods. The prostheses exhibited a step-wise migration pattern with migration steps of about 50 microns after every resting period, whereas the continuously loaded prostheses showed a more gradual migration pattern. The final subsidence of the specimens when loaded with resting periods was significantly less than the subsidence measured without resting periods. However, these specimens were loaded with fewer loading cycles. If this was taken into account, the discontinuously loaded specimens had a four fold higher average migration per loading cycle than the specimens that were loaded continuously. In conclusion, the resting periods had a considerable effect on the migration patterns, which should be realized when these stems are analyzed with pre-clinical tests.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Movement pattern of the Exeter femoral stem; a radiostereometric analysis of 22 primary hip arthroplasties followed for 5 years..

BACKGROUND The design of the Exeter stem may facilitate distal migration, but radiostereometric analysis (RSA) studies have been limited to 2 years of follow-up. PATIENTS AND METHODS We followed migration of the Exeter femoral stems in 22 primary hip arthroplasties for 5 years with RSA. RESULTS All stems migrated distally and the median migration at 2 years was 1.34 mm, while at 5 years it ...

متن کامل

Cement migration after THR. A comparison of charnley elite and exeter femoral stems using RSA.

Studies using roentgen stereophotogrammetric analysis (RSA) have shown that the femoral components of cemented total hip replacements (THR) migrate distally relative to the bone, but it is not clear whether this occurs at the cement-implant or the cement-bone interface or within the cement mantle. Our aim was to determine where this migration occurred, since this has important implications for ...

متن کامل

Ten-year RSA-measured migration of the Exeter femoral stem.

The Exeter femoral stem is a double-tapered highly polished collarless cemented implant with good long-term clinical results. In order to determine why the stem functions well we have undertaken a long-term radiostereometric analysis (RSA) study. A total of 20 patients undergoing primary Exeter total hip replacement for osteoarthritis using the Hardinge approach were recruited and followed with...

متن کامل

Randomised controlled trial comparing early migration of two collarless polished cemented stems using radiostereometric analysis.

This was a safety study where the hypothesis was that the newer-design CPCS femoral stem would demonstrate similar early clinical results and micromovement to the well-established Exeter stem. Both are collarless, tapered, polished cemented stems, the only difference being a slight lateral to medial taper with the CPCS stem. A total of 34 patients were enrolled in a single-blinded randomised co...

متن کامل

Design-related risk factors for revision of primary cemented stems

BACKGROUND AND PURPOSE Even small design variables of the femoral stem may influence the outcome of a hip arthroplasty. We investigated whether design-related factors play any role in the risk of non-aseptic revision of the 3 most frequently used primary cemented stem designs in the Swedish Hip Arthroplasty Register. PATIENTS AND METHODS We studied 71,184 primary cemented femoral stem implant...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 68 4  شماره 

صفحات  -

تاریخ انتشار 2002