Advantages of Arthroscopic Transosseous Suture Repair of the Rotator Cuff without the Use of Anchors
نویسندگان
چکیده
BACKGROUND Although arthroscopic anchor suturing is commonly used for rotator cuff repair and achieves good results, certain shortcomings remain, including difficulty with reoperation in cases of retear, anchor dislodgement, knot impingement, and financial cost. In 2005, we developed an anchorless technique for arthroscopic transosseous suture rotator cuff repair. DESCRIPTION OF TECHNIQUE After acromioplasty and adequate footprint decortication, three K-wires with perforated tips are inserted through the inferior margin of the greater tuberosity into the medial edge of the footprint using a customized aiming guide. After pulling the rotator cuff stump laterally with a grasper, three K-wires are threaded through the rotator cuff and skin. Thereafter, five Number 2 polyester sutures are passed through three bone tunnels using the perforated tips of the K-wires. The surgery is completed by inserting two pairs of mattress sutures and three bridging sutures. METHODS We investigated the retear rate (based on MR images at least 1 year after the procedure), total score on the UCLA Shoulder Rating Scale, axillary nerve preservation, and issues concerning bone tunnels with this technique in 384 shoulders in 380 patients (174 women [175 shoulders] and 206 men [209 shoulders]). Minimum followup was 2 years (mean, 3.3 years; range, 2-7 years). Complete followup was achieved by 380 patients (384 of 475 [81%] of the procedures performed during the period in question). The remaining 91 patients (91 shoulders) do not have 1-year postsurgical MR images, 2-year UCLA evaluation or intraoperative tear measurement, or they have previous fracture, retear of the rotator cuff, preoperative cervical radiculopathy or axillary nerve palsy, or were lost to followup. RESULTS Retears occurred in 24 patients (24 shoulders) (6%). The mean overall UCLA score improved from a preoperative mean of 19.1 to a score of 32.7 at last followup (maximum possible score 35, higher scores being better). Postoperative EMG and clinical examination showed no axillary nerve palsies. Bone tunnel-related issues were encountered in only one shoulder. CONCLUSIONS Our technique has the following advantages: (1) reoperation is easy in patients with retears; (2) surgical materials used are inexpensive polyester sutures; and (3) no knots are tied onto the rotator cuff. This low-cost method achieves a low retear rate and few bone tunnel problems, the mean postoperative UCLA score being comparable to that obtained by using an arthroscopic anchor suture technique.
منابع مشابه
Arthroscopic bone tunnel augmentation for rotator cuff repair.
Transosseous repair of the rotator cuff has been shown to recreate the anatomic rotator cuff footprint in a secure and cost-efficient manner. However, the potential for sutures cutting through bone remains a concern with this strategy. Devices have been used successfully during open transosseous rotator cuff repair to augment the bone tunnels, potentially avoiding suture cut-out through the wea...
متن کاملBiomechanical evaluation of transosseous rotator cuff repair: do anchors really matter?
BACKGROUND Suture anchor fixation has become the preferred method for arthroscopic repairs of rotator cuff tears. Recently, newer arthroscopic repair techniques including transosseous-equivalent repairs with anchors or arthroscopic transosseous suture passage have been developed. PURPOSE To compare the initial biomechanical performance including ultimate load to failure and localized cyclic e...
متن کاملTendon-bone interface motion in transosseous suture and suture anchor rotator cuff repair techniques.
BACKGROUND Although many studies involving rotator cuff repair fixation have focused on ultimate fixation strength and ability to restore the tendon's native footprint, no studies have characterized the stability of the repair with regard to motion between the tendon and repair site footprint. HYPOTHESIS Suture anchor fixation for rotator cuff repair has greater interface motion between tendo...
متن کاملInitial fixation strength of massive rotator cuff tears: in vitro comparison of single-row suture anchor and transosseous tunnel constructs.
PURPOSE The purpose of this study was to compare the in vitro repair integrity of massive rotator cuff tears fixed with transosseous tunnel and single-lateral row suture anchor techniques. METHODS A 5 x 2-cm crescent-shaped rotator cuff tear was created in 6 matched pairs of cadaveric shoulders. Paired shoulders were repaired with 3 transosseous tunnels and 6 Mason-Allen sutures or with 3 scr...
متن کامل“trAnsosseous-equivAlent” rotAtor cuff repAir
tears remains challenging, because the high re-tear rate following rotator cuff repair is due to multiple factors. Aspects such as poor tendon biology, muscular fatty infiltration and retraction, and nonanatomical repairs ultimately lead to inferior repair biomechanics. Although many of these factors remain beyond the control of the surgeon, certain repair constructs have been shown to decrease...
متن کاملArthroscopic Transosseous Rotator Cuff Repair
BACKGROUND Mechanical factors are at the basis of any tendon healing process, being pressure an aspect able to positively influence it. For this reason transosseous rotator cuff repair represents the gold standard procedure for patients affected by a cuff tear, maximizing the tendon footprint contact area and reducing motion at the tendon to bone interface. METHODS The Authors present an all ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 471 شماره
صفحات -
تاریخ انتشار 2013