FDG PET is a robust tool for the diagnosis of spondylodiscitis: a meta-analysis of diagnostic data.

نویسندگان

  • Michael L Prodromou
  • Panayiotis D Ziakas
  • Loukia S Poulou
  • Petros Karsaliakos
  • Loukas Thanos
  • Eleftherios Mylonakis
چکیده

PURPOSE Spondylodiscitis is a rare infectious entity that requires multimodal diagnostic procedures. We evaluated the diagnostic performance of 18F-FDG PET on suspected spondylodiscitis based on published literature. PATIENTS AND METHODS We searched the PubMed and EMBASE for pertinent studies up to July 2013. We implemented a patient-based meta-analysis of diagnostic data for FDG PET (the index test) against clinical, laboratory, and/or radiologic evidence of disease (the reference standard). A bivariate analysis was implemented to account for variability beyond the threshold effect. The individual patient data analysis was used to assess confounding factors that moderate diagnostic performance. RESULTS Twelve studies provided the diagnostic data on FDG PET and spondylodiscitis, comprising 224 patients. The combined sensitivity across studies was 0.97 [95% confidence interval (CI), 0.83-1.00], the specificity was 0.88 (95% CI, 0.74-0.95), and the area under the curve was 0.98 (95% CI, 0.96-0.99). For prior probabilities greater than 0.50, the corresponding positive predictive value was 0.96 (0.93-0.98), and the negative predictive value was 0.85 (0.82-0.88). In the individual patient data analysis, metallic implants, dual PET/CT scanners and the addition of other imaging modalities to confirm disease were significant outcome moderators; only PET/CT remained significant in the adjusted analysis. PET/CT scanners improved the diagnostic performance, as opposed to the clinical data (age, sex, lesion site), which did not alter outcome. CONCLUSIONS FDG PET is a robust diagnostic test when spondylodiscitis is suspected and is excellent for exclusion of infectious spondylodiscitis given its low likelihood ratio negative (<0.1). Importantly, this diagnostic test is unaffected by other confounders, including the presence of implants, when PET/CT is used.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Molecular imaging approaches in the diagnosis of breast cancer: A systematic review and meta-analysis

Introduction:The accuracy of positron emission tomography with computed tomography (PET/CT), positron emission mammography (PEM), and breast specific-gamma imaging (BSGI) in diagnosing breast cancer has never been systematically assessed, the present systematic review was aimed to address this issue.  Methods:PubMed, Scopus and EMBASE were searched for st...

متن کامل

Detection of extra-cardiac hypermetabolic foci by [18F]FDG PET/CT in case of infective endocarditis and post antibiotic therapy response assessment

The diagnosis of prosthetic valve endocarditis continues to present a diagnostic challenge, due to the lower sensitivity of the modified Duke criteria and a higher percentage of negative or inconclusive echocardiography results. Diagnostic delay might result in significant morbidity/mortality. Imaging modalities like 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography/comput...

متن کامل

The diagnostic difference between 18F- FDG PET and 99mTc-HMPAO SPECT perfusion imaging in assessment of Alzheimer's disease

Introduction:Brain imaging with F-18 fluorodeoxyglucose (18F-FDG) positron ‎emission tomography or Tc-99m hexamethylpropyleneamine oxime (‎99mTc-HMPAO) SPECT is widely used for the evaluation of Alzheimer's ‎dementia (AD); we aim to assess superiority of one method over the ‎other. Methods: Twenty four patients with clinical diagnosi...

متن کامل

A comparison of the diagnostic value of MRI and 18F-FDG-PET/CT in suspected spondylodiscitis

PURPOSE The purpose of this study was to evaluate the diagnostic value of 18F-fluorodeoxyglucose (FDG) positron emission tomography and computed tomography (PET/CT scan) and magnetic resonance imaging (MRI) in diagnosing spondylodiscitis and its complications, such as epidural and paraspinal abscesses. METHODS From January 2006 to August 2013 patients with a clinical suspicion of spondylodisc...

متن کامل

F-18 FDG PET/CT Imaging of Eccrine Sweat Gland Carcinoma of the Scrotum with Extensive Regional and Distant Metastases

Eccrine carcinoma is an extremely rare malignant skin cancer arising from eccrine sweat glands with a high metastatic potential. It mainly occurs in the elderly, with equal incidence in both sexes. It usually spreads to regional lymph nodes, with liver, lungs, and bones being the most common sites of distant metastasis. Because of tumor rarity, little is known about the value of F18- FDG PET/CT...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical nuclear medicine

دوره 39 4  شماره 

صفحات  -

تاریخ انتشار 2014