Accuracy of oximetry for detection of respiratory disturbances in sleep apnea syndrome.
نویسندگان
چکیده
STUDY OBJECTIVE The cost and inconvenience of polysomnography make simplified techniques of screening desirable in the strategy of diagnosis of sleep apnea syndrome (SAS). We have evaluated, in a prospective study of 301 consecutive patients referred for suspected sleep disorders, an index (delta index) that detects apneic events by quantifying arterial oxygen saturation (SaO2) variability. SETTING Regional sleep laboratory taking referrals from general practitioners and specialists. DESIGN Classic polysomnography was the gold standard, with 15 apneas plus hypopneas per hour (RDI) being used as a threshold for definition of obstructive sleep apnea (OSA). Oximetry was recorded over the same night. Signal variability was quantified as a function of time, using digital processing of oximetric data. Sensitivity, specificity, and positive and negative predictive values of oximetry testing were calculated. A receiver operating characteristic (ROC) curve was constructed representing the comparative courses of sensitivity and 1-specificity at different thresholds of delta index. RESULTS Three hundred one patients were included (age, 56 +/- 12 years). Their RDI was 30 +/- 24. For a delta threshold at 0.6, the sensitivity of oximetry for the diagnosis of OSA was 98% and the specificity was 46%. The positive and negative predictive values for diagnosing SAS were 77% and 94%, respectively. The three false-negative cases had a relatively high awake SaO2 (97 vs 93.9 +/- 2.8%), a moderate RDI (23.3 +/- 1.6), and were less obese than the other patients (body mass index: 25 +/- 3 vs 33 +/- 8). The 58 false-positive cases had an RDI of 8 +/- 4, an awake SaO2 of 93.1 +/- 3.6 vs 94.1 +/- 2.6 for the rest of the population (p = 0.01). Finally, the false-positive cases had more airways obstruction (FEV1/VC = 72 +/- 13 vs 77 +/- 15%; p = 0.026). Using a delta value of 0.8 leads to a sensitivity of 90% with 19 false-negative cases but with a higher specificity of 75%. CONCLUSIONS A nocturnal oximetry test with a delta index below 0.6 is helpful in ruling out the diagnosis of SAS in patients being screened for this condition, as this yielded only three negative test results in 301 screening procedures.
منابع مشابه
ارزیابی آپنه تنفسی حین خواب در بیماران قلبی
Background and Objective: Obstructive sleep apnea, a common form of sleep disorder breathing, is highly prevalent in adults with approximately 20% adults having at least mild OSA. One of the most associated consequences is cardiovascular sequel. This study aimed to assessment of sleep apnea in Ischemic Heart Disease patients and whether pulse oximetry can predict apnea in this group of patients...
متن کاملValidity of Spo2/Fio2 Ratio in Detection of Acute Lung Injury and Acute Respiratory Distress Syndrome
Introduction: One ofdiagnostic criteria for Acute Lung Injury and Acute Respiratory Distress Syndrome is pao2/fio2 (PF) ratio 300 for ALI or 200 for ARDS. This criteria requires invasive arterial sampling. Measurement of Spo2/Fio2 (SF) ratio by pulseoximetry may be a reliable non invasive alternative to the PF ratio. Methods and Materials: In a cross sectional study we enrolled 105 sample o...
متن کاملClassification methods to detect sleep apnea in adults based on respiratory and oximetry signals: a systematic review.
OBJECTIVE Sleep apnea (SA), a common sleep disorder, can significantly decrease the quality of life, and is closely associated with major health risks such as cardiovascular disease, sudden death, depression, and hypertension. The normal diagnostic process of SA using polysomnography is costly and time consuming. In addition, the accuracy of different classification methods to detect SA varies ...
متن کاملObstructive sleep apnea syndrome and non-arteritic anterior ischemic optic neuropathy: a case control study
Background: Sleep apnea is temporary cessation or absence of breathing during sleep. Significant increase in blood pressure is clinically seen in apneic episodes. The aim of this study was to examine sleep apnea syndrome as a risk factor for non- arthritic anterior ischemic optic neuropathy (NAION) in a case control study. Methods: Nineteen NAION patients (9 men and 10 women) and 31 age and ...
متن کاملQuantification of sleep disordered breathing by computerized analysis of oximetry, heart rate and snoring.
Intermittent snoring and cyclic oscillations of heart rate and oxyhaemoglobin saturation (Sao2) are characteristic features of the obstructive sleep apnoea syndrome (OSAS). Thus, overnight recordings of laryngeal sounds and heart rate by a portable device (MESAM) and of Sao2 by oximetry are applicable to screen outpatients for the presence of OSAS. Computerized analysis for time intervals of co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 109 2 شماره
صفحات -
تاریخ انتشار 1996