Flow-Injection Solid Phase Partial Least-Squares Spectrophotometric Simultaneous Determination of Iron, Nickel and Zinc

نویسندگان

  • Leonardo S. G. Teixeira
  • Antonio C. S. Costa
  • Salvador Garrigues
  • Miguel de la Guardia
چکیده

Solid phase spectrophotometry (SPS) provides effective methods to combine metal ion preconcentration and their spectrophotometric determination, by integrating the formation of colored complexes and their fixation on the surface of a solid support placed inside the measurement cell. The coupling between flow injection analysis (FIA) and SPS (FI-SPS) makes it unnecessary to reach equilibrium conditions, thus providing faster and more selective methods than those found in batch conditions. Additionally, it offers a simple and easy way of automation and provides low detection limits, small amounts of samples and reagents being employed. Since flow injection analysis was introduced, the simultaneous determination of several analytes in a same sample has been a challenge in order to make FIA competitive with other analytical techniques. In this way, the use of SPS and FIA has been applied in several studies for the determination of binary mixtures of metal ions, amines and mixtures of dyes. Approaches employed for multicomponent determination in solution can be also applied in FI-SPS. Flow-Injection Solid Phase Partial Least-Squares Spectrophotometric Simultaneous Determination of Iron, Nickel and Zinc

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares

A partial least squares (PLS) calibration model was developed for the simultaneous spectrophotometricdetermination of Pb (ΙΙ), Cu (ΙΙ) and Ni (ΙΙ) using xylenol orange as a chromogenic reagent. The parameterscontrolling behavior of the system were investigated and optimum conditions were selected. The calibrationgraphs were linear in the ranges of 0.0–9.091, 0.0–2.719 and 0.0–2.381 ppm for lead...

متن کامل

Simultaneous Spectrophotometric Determination of Iron, Cobalt and Copper by Partial Least-Squares Calibration Method in Micellar Medium

Iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. Recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. The organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. The ability of mi...

متن کامل

Simultaneous Spectrophotometric Determination of Iron, Cobalt and Copper by Partial Least-Squares Calibration Method in Micellar Medium

Iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. Recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. The organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. The ability of mi...

متن کامل

Spectrophotometric simultaneous determination of nickel, cobalt and copper by orthogonal signal correction–partial least squares

A method for the simultaneous spectrophotometric determination of nickel, cobalt and copper based on theformation of their complexes with 2-(2-Thiazolylazo)-p-Cresol (TAC) in micellar media of Triton X-100 isproposed. The absorbance spectra were recorded in the range of 500 to 800 nm. The linear concentrationrange for nickel, cobalt and copper in solution calibration sets were 0.05–1.80, 0.10–6...

متن کامل

Simplex design method in simultaneous spectrophotometric determination of silicate and phosphate in boiler water of power plant and sewage sample by partial least squares

Partial least squares modeling as a powerful multivariate statistical tool was applied tothe simultaneous spectrophotometric determination of silicate and phosphate in aqueoussolutions. The concentration range for silicate and phosphate were 0.02-0.6 and 0.4-3 μg ml-1,respectively. The experimental calibration set was composed with 30 sample solutions using amixture design for two component mix...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002