16-Year Trends in the Infection Burden for Pacemakers and Implantable Cardioverter-Defibrillators in the United States
نویسنده
چکیده
Methods The Nationwide Inpatient Sample (NIS) discharge records were queried between 1993 and 2008 using the 9th Revision of the International Classification of Diseases (ICD-9-CM). CIED infection was defined as either: 1) ICD-9 code for device-related infection (996.61) and any CIED procedure or removal code; or 2) CIED procedure code along with systemic infection. Patient health profile was evaluated by coding for renal failure, heart failure, respiratory failure, and diabetes mellitus. The infection burden and patient health profile were calculated for each year, and linear regression was used to test for changes over time.
منابع مشابه
Erosive Pressure Dermatitis Associated with Cardiac Pacemaker
Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...
متن کامل16-year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States 1993 to 2008.
OBJECTIVES We analyzed the infection burden associated with the implantation of cardiac implantable electrophysiological devices (CIEDs) in the United States for the years 1993 to 2008. BACKGROUND Recent data suggest that the rate of infection following CIED implantation may be increasing. METHODS The Nationwide Inpatient Sample (NIS) discharge records were queried between 1993 and 2008 usi...
متن کاملIncidence and Costs Related to Lead Damage Occurring Within the First Year After a Cardiac Implantable Electronic Device Replacement Procedure.
BACKGROUND Inadvertent damage to leads for transvenous pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy defibrillators is an important complication associated with generator-replacement procedures. We sought to estimate the incidence and costs associated with transvenous lead damage following cardiac implantable electronic device replacement. METHODS ...
متن کاملStaphylococcus aureus bacteremia in patients with permanent pacemakers or implantable cardioverter-defibrillators.
BACKGROUND Although cardiac device infections (CDIs) are a devastating complication of permanent pacemakers or implantable cardioverter-defibrillators, the incidence of CDI in patients with bacteremia is not well defined. The objective of this study was to determine the incidence of CDI among patients with permanent pacemakers or implantable cardioverter-defibrillators who develop Staphylococcu...
متن کاملSafety of magnetic resonance imaging in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices.
Magnetic resonance imaging (MRI) in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices is sometimes a risky procedure. Thus MRI in these patients should be performed when it is the only examination able to help with the diagnosis. Moreover the diagnostic benefit must outweigh the risks. Coronary artery stents, prosthetic cardiac valves, metal sternal sutur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -