The integral equations of Compton Scatter Tomography
نویسندگان
چکیده
Two new Compton Scatter Tomography modalities, which are aimed at imaging hidden structures in bulk matter for industrial non-destructive control (or testing) and for medical diagnostics are shown to be based on the solutions of a special class of Chebyshev integral transforms. Besides their remarkable analytic properties, they can be inverted by existing methods which lend themselves nicely to numerical treatment and provide convergent, stable and fast computation algorithms. The existence of explicit inversion formulas implies that viable new imaging techniques can be developed, which may take over the current ones in a near future. Keywords-Integral transforms; Radon transforms; Compton scatter imaging; Non-destructive testing; Medical imaging.
منابع مشابه
A Generalized Model for 3D Compton Scatter in Single Photon Emission Computed Tomography Using Slice-by-Slice Blurring and Scatter Projection Rebinning
The modeling of 3D Compton scatter in SPECT is complicated by the use of a variety of collimator geometry. To date, effective and efficient modeling of 3D Compton scatter in parallel-beam SPECT has been made possible by Frey and Tsui [1], Zeng et al [2], and Bai et al [3]. For fan-beam and cone-beam SPECT, the model in [3] can effectively model first order 3D Compton scatter. But for varying-fo...
متن کاملSimulation and patient studies of scatter correction in cardiac SPECT imaging
Introduction: Myocardial perfusion imaging is a nuclear medicine imaging method that is used to detect coronary artery diseases. One of the main sources of error in this imaging method is the detection of Compton scattered photons in the photopeak energy window used for data acquisition. This results in the degradation of the image contrast, and therefore decreases the...
متن کاملDelayed imaging and additional methods to reduce subdiaphragmatic activity in myocardial perfusion SPECT imaging
Compton scatter from radiotracer in structures close to the heart may partially or completely mask myocardial perfusion defects on SPECT imaging. Previous reports have discussed benefits of additional delayed imaging. We present a case in which additional delayed stress imaging reduced Compton scatter and unveiled clinically significant, stress-induced ischemia.
متن کاملStabilizing dual-energy X-ray computed tomography reconstructions using patch-based regularization
Recent years have seen growing interest in exploiting dualand multi-energy measurements in computed tomography (CT) in order to characterize material properties as well as object shape. Materials characterization is performed by decomposing the scene into constitutive basis functions, such as Compton scatter and photoelectric absorption functions. While well motivated physically, the joint reco...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012