Cardiac Resynchronization Therapy Device Implantation in a Patient with Cardiogenic Shock under Percutaneous Mechanical Circulatory Support
نویسندگان
چکیده
65-year-old woman was admitted to our hospital with acute decompensated heart failure with reduced left ventricular ejection fraction and severe mitral regurgitation. Electrocardiography revealed a typical left bundle branch block and atrial fibrillation. Her condition deteriorated despite administering high-doses of inotropes and vasopressors. Pending a decision to therapy, venoarterial extracorporeal membrane oxygenation (ECMO) was performed when the patient underwent a cardiogenic shock. Although the hemodynamic status stabilized with ECMO support, weaning the patient from ECMO was not possible. Thus, we decided to perform cardiac resynchronization with defibrillator implantation as a "rescue" therapy. Five days post-implantation, the patient was successfully weaned from ECMO.
منابع مشابه
The contemporary role of Impella in a comprehensive mechanical circulatory support program: a single institutional experience
BACKGROUND The treatment of cardiogenic shock with percutaneous mechanical circulatory support (MCS) is attractive: however, at present it is not clear which is the best strategy, as no survival benefit has been demonstrated for any device as single therapy. Aim of this study is to describe the role of percutaneous Impella in a comprehensive MCS program. METHODS Observational study on 22 pati...
متن کاملPercutaneous Mechanical Circulatory Support Devices in Cardiogenic Shock.
Despite a high rate of early revascularization and use of intra-aortic balloon pump counterpulsation therapy, the prognosis of patients with cardiogenic shock has remained poor. In the hopes of improving outcomes, clinicians are increasingly turning to percutaneous left and right mechanical circulatory support devices. Until recently, the evidence base for these devices had consisted only of ob...
متن کاملNonpharmacologic management of cardiac arrest and cardiogenic shock.
P harmacologic management of patients with cardiac arrest or cardiogenic shock may be insuI cient in restoring adequate circulatory support. This has led physicians to investigate and develop more aggressive interventions for these problems. Cardiogenic shock most frequently occurs in the following clinical settings: (1) acute myocardial infarction; (2) postcardiotomy; (3) an acute exacerbation...
متن کاملTreatment of cardiogenic shock with left ventricular assist device combined with cardiac resynchronization therapy: A case report
Cardiogenic shock has a poor prognosis with established treatment strategies. We report a 62 years old man with heart failure exacerbating into refractory cardiogenic shock successfully treated with the combination of a percutaneous left ventricular assist device (LVAD) and subacute cardiac resynchronization therapy (CRT) implantable cardioverter-defibrillator device (CRT-D).
متن کاملMechanical circulatory support in acute cardiogenic shock
Cardiogenic shock complicates about 5% to 8% of all admissions for acute myocardial infarction, and despite advancement in treatment over the past 50 years, mortality remains unacceptably high. Management with vasoactive agents after revascularization can have its limitations and thus mechanical circulatory support is often initiated. Intra-aortic balloon pumps (IABPs) are the devices most comm...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 47 شماره
صفحات -
تاریخ انتشار 2017