Self management of oral anticoagulant therapy after heart valve replacement.

نویسندگان

  • J M Hasenkam
  • H H Kimose
  • L Knudsen
  • H Grønnesby
  • J Halborg
  • T D Christensen
  • J Attermann
  • H K Pilegaard
چکیده

OBJECTIVE Patients with mechanical heart valves require lifelong oral anticoagulant treatment which entails frequent blood sampling and dosage adjustment. The purpose of this study was to investigate the feasibility of letting heart valve operated patients manage blood specimen analysis and dosage adjustment themselves. METHODS A total of 21 patients were enrolled in the study and followed for at least 9 months postoperatively. Immediately after the heart valve operation they were trained in operating a CoaguChek international normal ratio (INR) monitor to analyze capillary whole blood samples. Subsequently training in dosage adjustment was accomplished and all patients were considered fully capable of self management after 30 weeks. In the training period, parallel laboratory INR measurements were made at 3-4 week intervals for reference. A control group of 20 patients was matched, respectively, to the study group. The INR target range was 2.0-3.0. RESULTS Out of the 21 study patients 19 continued self management beyond 9 months. The median INR value obtained with the monitor was within therapeutic target range for all study patients and only 15 out of 20 control patients were within this range. The mean systematic deviation between laboratory and CoaguChek INR was 7.8% but each patient had a constant characteristic deviation from -11 to +21%. The study patients were within therapeutic target range 77% of the time compared with 53% for the control patients. CONCLUSIONS Self management of oral anticoagulation is feasible for selected patients and constitutes a significant service improvement compared with conventional management. The CoaguChek monitor seems sufficiently accurate and reliable for self testing and the treatment quality is comparable or even better than conventional management. Assessment of the rate of bleeding and thrombo-embolic events shall be settled in studies comprising larger number of patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of a Nurse-led Patient Education Program for Oral Anticoagulant Therapy on the Incidence of Thromboembolic and Hemorrhagic Episodes after Surgical Heart Valve Replacement

Introduction: Although, the effects of patient education on the effective anticoagulant management, among patients undergoing heart valve replacement with a mechanical prosthesis, have been reported, the evidence of this association remains inconclusive. Aim: To investigate the effect of a nurse-led patient education program for oral anticoagulant therapy on the incidence of thromboembolic and ...

متن کامل

Oral Anticoagulation after Mechanical Heart Valve Replacement: Low Intensity Regimen can Make the Difference

Despite continuous improvement in the field, the ideal prosthetic heart valve remains to be developed. Patients with mechanical prosthetic heart valves are at risk of thrombosis and systemic embolism. The incidence rate of these serious complications is significantly reduced by lifelong Oral Anticoagulant Therapy (OAC) vitamin K antagonist (VKA) therapy. Despite its undeniable benefits, VKA the...

متن کامل

Anticoagulant Therapy-Induced Gallbladder Hemorrhage after Cardiac Valve Replacement

Anticoagulation therapy is essential after cardiac valve surgery. However, spontaneous bleeding remains a major concern during anticoagulation therapy. Spontaneous gallbladder (GB) hemorrhage (hemobilia) is a rare occurrence during standard anticoagulation therapy. This report presents a case of GB hemorrhage that occurred shortly after initiating oral anticoagulant therapy in a patient who had...

متن کامل

Transcranial Doppler application for risk assessment of stroke in patients with mechanical mitral valve

Introduction: Observing microembolic signals in brain vessels by transcranial Doppler technology is a very common finding in patients with mechanical heart valve. These signals are almost always clinically asymptomatic. The aim of this study was assessment of transcranial Doppler in detecting probability of stroke in patients with mechanical heart valve. Methods: This descriptive study was ca...

متن کامل

Comparison of Group and Individual Training on the Patients’ Compliance and Incidence of Warfarin Side Effects after Cardiac Valve Replacement

Introduction: Oral anticoagulant therapies are intended for prevention of thrombotic adverse effects and to maintain the level of drug without bleeding. The probability of risk highly depends on the patient compliance after discharge from hospital. This study was designed to compare the effect of group and individual education on patients’ compliance and incidence of adverse effects of warfarin...

متن کامل

Pregnancy Outcome with Intracytoplasmic Sperm Injection Method in a Woman with Prosthetic Heart Valves

There is an increased risk of thromboembolism, anticoagulant-related hemorrhage, fetal-wastage and congestive cardiac failure in pregnant women with mechanical heart valves. In order to have a good outcome, the care of such patients must necessarily be multidisciplinary and in a well- equipped centre with adequate support services .One such patient who had mechanical mitral and aortic valves re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 11 5  شماره 

صفحات  -

تاریخ انتشار 1997