Point-of-Care Ultrasound to Evaluate a Teenager with Presyncope
نویسندگان
چکیده
A 16-year-old male presented with three months of palpitations at rest, fatigue, and episodic pre-syncope; his paternal grandfather died following presumed premature myocardial infarction at age 30. He was seen and discharged one week previously at an outside emergency department (ED). He followed up with his pediatrician and was promptly referred to our pediatric ED for evaluation given his risk factors. Pertinent vitals on arrival were pulse 110, blood pressure 129/66, and oxygen saturation 97% on room air. His exam was remarkable for a left upper sternal border 2/6 holosystolic murmur with radiation to apex. In addition, the patient had a chest radiograph (Figure), a nonspecific but abnormal EKG, and a point-of-care ultrasound (POCUS) of the heart performed. POCUS (Video) suggested hypertrophic cardiomyopathy (HCM); this was confirmed by comprehensive echocardiogram that showed 4.7cm septal hypertrophy with intraventricular Rady Children’s Hospital, Division of Emergency Medicine, San Diego, California University of California at San Diego, Department of Emergency Medicine, San Diego, California
منابع مشابه
Adaptive beamforming in row-column addressed arrays for 3D ultrasound imaging
In recent years, to reduce the complexity of implementation, the use of 2D arrays with restricted row-column addressing has been considered for 3D ultrasound imaging. In this paper, two methods of adaptive beamforming based on the minimum variance method are represented in such a way that the computational load is much less than using the full adaptive beamforming method. In both proposed metho...
متن کاملComparison of the Diagnostic Values of Four-Point and Two-point Ultrasound Versus CT Scan in Determining Pneumothorax
Background and Objectives: Pneumothorax is a life-threatening complication and the most common cause of which is trauma. Early diagnosis and treatment of Pneumothorax are very important. The aim of this study was to compare the diagnostic values of four-point and double-point ultrasound versus CT scan in determining pneumothorax in Rasul-Akram and Hafte-Tir Hospitals during the years 2015 - 201...
متن کاملAccuracy of point-of-care ultrasound for diagnosis of skull fractures in children.
OBJECTIVE To determine the test performance characteristics for point-of-care ultrasound performed by clinicians compared with computed tomography (CT) diagnosis of skull fractures. METHODS We conducted a prospective study in a convenience sample of patients ≤21 years of age who presented to the emergency department with head injuries or suspected skull fractures that required CT scan evaluat...
متن کاملI-18: Techniques and Technologies for Embryo Transfer: Does It Really Matter.
The learning objectives of this presentation are to understand the dynamics involved in the process of ET, evaluate the evidence for/against common practices and techniques and develop a standardized ET process in view of supporting evidence. Gametes and embryos are handled with extreme care at every step of the Laboratory process. ET is the least sophisticated step of the in vitro Fertilizatio...
متن کاملThe effectiveness of time-perspective therapy on cognitive abilities, emotion regulation and alexithymia in depressed teenager girls
Background & Aim: Depressed people are faced with problems in cognitive abilities,emotion regulation and alexithymia.According to previous studies, time perspective as a person's view of his past, present, and personal futurecan help him in improving his cognitive abilities and emotion regulation. The aim of this study was to evaluate the effectiveness of time horizon therapy on cognitive abili...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -
تاریخ انتشار 2016