A Simplified In Vitro System for Evaluating Gas Transfer Characteristics of Oxygenators

نویسندگان

  • G. S. Bhuvaneshwar
  • M. S. Valiathan
چکیده

Despite the excellent performance of membrane oxygenators, bubble oxygenators continue to dominate routine open heart surgery. Newer versions with reduced gas:blood flow ratios continue to appear for clinical application 1•2. The new models generally provide data on partial pressure of oxygen (p02) of oxygenated blood at given blood and oxygen flow rates from clinical perfusions37. Clinical data has admitted drawbacks in evaluating the candidate oxygenator. Thus there would seem to be a need for a simple in vitro system for evaluating the performance of an oxygenator. Such a system should offer close control over such parameters as hemoglobin content, temperature pH, pCo2, p02 and percentage oxygen saturation. Control of such functional parameters is difficult, if not impossible in ex vivo experiments, thanks to the variable hemodynamic responses of the experimental animals. This paper describes a simple in vitro test setup which offers easier and more accurate control of blood gas parameters than the conventional ex vivo and in vitro systems. Figure I illustrates a conventional circuit used for the evaluation of an oxygenator810• 14. The blood circuit incorporates a deoxygenator system consisting of two bubble oxygenators and venous and arterial reservoirs. A calibrated pump gives controlled blood flow into the test oxygenator. About 4-6 liters of blood are used to

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of perfluorocarbon emulsion properties for enhancing oxygen mass transfer in a bio-artificial liver support system

The oxygen carrying performance of a perfluorooctyl bromide (PFOB) emulsion is considered. The intended purpose is to enhance hepatocyte growth and function in a bio-artificial liver support system (BALSS). Such oxygen carrying emulsions have previously been used in biological systems (e.g. cell culturing). However, optimum emulsion characteristics for enhanced oxygen mass transfer have not bee...

متن کامل

An in vitro comparison of gas transfer and pressure drop of the Bentley Duraflo Coated Spiral Gold and the Medtronic Carmeda Coated Maxima hollow fiber membrane oxygenators.

Two models of heparin coated, hollow fiber membrane oxygenators were tested in vitro to compare gas transfer and transoxygenator pressure drop using an established protocol. Oxygen and carbon dioxide transfer rates were measured at blood flows of 2.5 and 5.0 liters per minute with gas flow: blood flow ratios of 1:1 and 2:1 at both blood flows. All testing was performed under normothermic condit...

متن کامل

Non-destructive evaluation of membrane lung gas exchange performance.

This paper describes a method of evaluating the gas exchange effectiveness of hollow fiber oxygenators utilizing gas on both sides of the membrane. The goal of the study was to develop an evaluation technique which was accurate, reliable, and did not harm or contaminate a new, sterile oxygenator. Three pediatric oxygenators were tested and compared: the Medtronic Minimax Plus, the Terumo Capiox...

متن کامل

Experimental Investigation and Modeling of Carbon Dioxide Adsorption from Model Flue gas

In this work, the adsorption of carbon dioxide from model flue gas on different adsorbents has been investigated. Using simplified modeling, parameters such as the total mass transfer coefficient and the effective diffusivity have been determined. Experiments were carried out in two sections: firstly, adsorption of pure carbon dioxide on different adsorbents was measured at pressures ranging fr...

متن کامل

Evaluating in vitro dose-response effects of Lavandula officinalis essential oil on rumen fermentation characteristics, methane production and ruminal acidosis

Four in vitro experiments (Exp.) were conducted to evaluate lavender essential oil (LEO) effects at 0 (control), 250 (low dose), 500 (medium dose), 750 and 1000 µL per L(high doses) of incubation medium on rumen gas production kinetics (Exp.1), ruminal digestibility and fermentation (Exp.2), methane production (Exp.3) and rumen acidosis (Exp.4). The asymptote of gas production (A) incr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999