Comparison of self-refraction using a simple device, USee, with manifest refraction in adults

نویسندگان

  • Anvesh Annadanam
  • Varshini Varadaraj
  • Lucy I Mudie
  • Alice Liu
  • William G Plum
  • J Kevin White
  • Megan E Collins
  • David S Friedman
چکیده

BACKGROUND The USee device is a new self-refraction tool that allows users to determine their own refractive error. We evaluated the ease of use of USee in adults, and compared the refractive error correction achieved with USee to clinical manifest refraction. METHODS Sixty adults with uncorrected visual acuity <20/30 and spherical equivalent between -6.00 and +6.00 diopters completed manifest refraction and self-refraction. RESULTS Subjects had a mean (±SD) age of 53.1 (±18.6) years, and 27 (45.0%) were male. Mean (±SD) spherical equivalent measured by manifest refraction and self-refraction were -0.90 D (±2.53) and -1.22 diopters (±2.42), respectively (p = 0.001). The proportion of subjects correctable to ≥20/30 in the better eye was higher for manifest refraction (96.7%) than self-refraction (83.3%, p = 0.005). Failure to achieve visual acuity ≥20/30 with self-refraction in right eyes was associated with increasing age (per year, OR: 1.05; 95% CI: 1.00-1.10) and higher cylindrical power (per diopter, OR: 7.26; 95% CI: 1.88-28.1). Subjectively, 95% of participants thought USee was easy to use, 85% thought self-refraction correction was better than being uncorrected, 57% thought vision with self-refraction correction was similar to their current corrective lenses, and 53% rated their vision as "very good" or "excellent" with self-refraction. CONCLUSION Self-refraction provides acceptable refractive error correction in the majority of adults. Programs targeting resource-poor settings could potentially use USee to provide easy on-site refractive error correction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Manifest refraction versus autorefraction for patients with subfoveal choroidal neovascularization.

PURPOSE To compare the results from manifest refraction using trial lenses and a standard visual acuity protocol to results from autorefraction for obtaining refractive error and best corrected visual acuity in patients enrolled in a randomized clinical trial. METHODS During a 4-month period, 29 patients with subfoveal choroidal neovascularization (CNV), who were enrolled in the Submacular Su...

متن کامل

Accuracy of WASCA aberrometer refraction compared to manifest refraction in Chinese adult myopes.

PURPOSE To investigate the accuracy of the Carl Zeiss Meditec Wavefront Supported Custom Ablation (WASCA) aberrometer in refraction testing for Chinese myopic adults. METHODS Manifest refraction and WASCA were performed on 360 eyes of 360 consecutive Chinese myopic adults without cycloplegia. Both vector analysis and conventional notation were applied for comparing results, and differences be...

متن کامل

Refraction at the Interface of a Lossy Metamaterial

The refraction phenomenon at the interface of an ordinary material and a lossy metamaterial has been investigated. For oblique incidence on the lossy metamaterial, the planes of constant amplitude of the refracted wave are parallel to the interface and the plane of constant phases make a real angle with the interface (real refraction angle). The real refraction angle and hence, the real refract...

متن کامل

Joint inversion of ReMi dispersion curves and refraction travel times using particle swarm optimization algorithm

Shear-wave velocity ( ) is an important parameter used for site characterization in geotechnical engineering. However, dispersion curve inversion is challenging for most inversion methods due to its high non-linearity and mix-determined trait. In order to overcome these problems, in this study, a joint inversion strategy is proposed based on the particle swarm optimization (PSO) algorithm. The ...

متن کامل

Investigation tow of negative refraction characters in the three different 2D phononic crystals

In this paper, a two-dimensional phononic crystal comprising of steel rod in water is investigated. Three cross- sections for this rod are considered using finite element method (EFM). We plot the equifrequency surface of the first band, because of equifrequency surface convex around the edge of the first Brillouin Zone, we guess the negative effective phononic mass and so negative refraction. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2018