Twenty four hour variation in plasma atrial natriuretic factor during VVI and DDD pacing.

نویسندگان

  • P E Vardas
  • M Markianos
  • E Skalidis
  • E Simantirakis
  • E Manios
  • E Papavasiliou
چکیده

OBJECTIVE To investigate whether plasma atrial natriuretic factor (ANF) follows a pattern of circadian variation similar to that of other hormones in patients paced under VVI and DDD pacing modes and to determine if the known effect of pacing mode on ANF secretion is maintained throughout the 24 hour period. PATIENTS AND DESIGN 20 patients were studied. They had complete atrioventricular block and had been paced for 17 (SD 3.5) months with a dual chamber multiprogrammable pacemaker. They were divided into two groups according to the duration of pacing in either VVI or DDD mode before the measurements: group A, n = 11 (8 men, 3 women, aged 65 (7) years), each paced for 24 h under each of VVI and DDD modes in random order; group B, n = 9 (7 men, 2 women, aged 63 (8) years), each paced for 60 d under each pacing mode before the measurements. Blood samples were taken and ANF concentrations measured every 4 h over a 24 h period, starting at 09.00. Measurements were also made of plasma cortisol, which has a known circadian pattern, so that the 24 h curve could be compared with that of ANF. RESULTS In contrast to cortisol, ANF values indicated a pulsatile pattern of secretion throughout the 24 h period, with no clear circadian variation. In group B, ANF concentrations were significantly higher during VVI than during DDD pacing throughout the 24 h period, whereas in group A this difference was statistically significant only at certain times of day. CONCLUSIONS ANF does not show the circadian pattern of variation shown by cortisol and other hormones. Dual chamber pacing contributes to an improvement not only in cardiac haemodynamics but also in the neuroendocrine system, especially in the long term.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of pacing mode and rate on peripheral levels of atrial natriuretic peptide (ANP).

The effect of acute modifications of pacing mode and rate on plasma ANP levels was evaluated. ANP was determined in ten resting patients with DDD pacemakers due to binodal disease or intermittent second-and third-degree AV block. At 82/minute pacing rate the ANP plasma levels (normal range 2 to 30 fmol/mL) corresponded to those under AAI (4.05 +/- 2.10 fmol/mL) and DDD (4.18 +/- 2.02 fmol/mL) p...

متن کامل

Benefits of dual chamber pacing in sick sinus syndrome.

The effects of DDD (fully automatic) and VVI (ventricular demand) pacing modes on exercise tolerance, symptom diary cards, and Holter monitoring were investigated in a randomised double blind crossover study of 16 patients who had had DDD pacemakers implanted because of frequent syncope. Eight patients presented with sick sinus syndrome and, with one exception, retrograde atrioventricular condu...

متن کامل

Atrial natriuretic peptide levels reflect hemodynamic changes under pacemaker stimulation.

Pacemaker stimulation influences plasma levels of atrial natriuretic peptide (ANP). This study evaluated in individuals without impaired myocardial function whether a consecutive increase of pacing rates results in reduced alteration of plasma ANP levels mirroring a putative decrease of atrial contribution to cardiac output. In nine resting patients with DDD pacemakers, absolute and relative AN...

متن کامل

Comparison of dual chamber and ventricular rate responsive pacing in patients over 75 with complete heart block.

OBJECTIVE To compare symptoms and exercise tolerance during dual chamber universal (DDD) and ventricular rate response (VVIR) pacing in elderly (> or = 75) patients. DESIGN Randomised, double blind, crossover study. SETTING Regional cardiac department. PATIENTS Twenty elderly patients (mean age 80.5 (1) years) with high grade atrioventricular block and sinus rhythm. Patients with pre-exis...

متن کامل

"Subclinical" pacemaker syndrome: a randomised study of symptom free patients with ventricular demand (VVI) pacemakers upgraded to dual chamber devices.

OBJECTIVE To determine whether symptom free patients with single chamber pacemakers benefit from dual chamber pacing. DESIGN A randomised double blind crossover comparison of ventricular demand (VVI), dual chamber demand (DDI), and dual chamber universal (DDD) modes after upgrading from a VVI device. SETTING Cardiology outpatient department. PATIENTS Sixteen patients aged 41-84 years who ...