Rapid determination of serum testosterone by liquid chromatography-isotope dilution tandem mass spectrometry and a split sample comparison with three automated immunoassays.

نویسندگان

  • Yu Chen
  • Mehrdad Yazdanpanah
  • Barry R Hoffman
  • Eleftherios P Diamandis
  • Pui-Yuen Wong
چکیده

OBJECTIVES To develop a rapid convenient-to-implement high performance liquid chromatography-isotope dilution tandem mass spectrometry (LC-IDMS/MS) method for determination of serum testosterone concentration in routine clinical laboratories. METHODS Following extraction by organic solvents, an Agilent 1200 Series HPLC system coupled to an API 5000 mass spectrometer equipped with an atmospheric pressure chemical ionization ion source was used to separate, detect and quantify serum testosterone. Ion-transitions of m/z 289.2-->109.1 and 294.2-->113.2 were used to monitor testosterone and testosterone-2,2,4,6,6-d(5), respectively. RESULTS Functional sensitivity was 0.056 nmol/L (CV 20%). Within-run and total imprecision were 4.6% and 5.2% at 1.3 nmol/L, 2.4% and 4.3% at 11.0 nmol/L, and 1.9% and 1.9% at 23.4 nmol/L respectively. The LC-MS/MS method agreed closely with three automated immunoassays when the concentration of testosterone exceeded 3 nmol/L. However, the immunoassays showed a positive bias at concentrations below 3 nmol/L. CONCLUSION This method provides a rapid, simple, highly selective and sensitive procedure that can be easily used for determination of serum testosterone in routine clinical laboratories. It measures serum testosterone precisely and accurately at concentrations found in children and adults of both genders.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of standardization of serum C-peptide immunoassays with isotope-dilution liquid chromatography-tandem mass spectrometry.

BACKGROUND Serum C-peptide concentrations reflect pancreatic function in different clinical and diagnostic settings; however, the utility of C-peptide testing is limited by the lack of standardized commercial immunoassays. Standardization can best be done by split-sample comparison with a hierarchically higher reference measurement procedure with a set of native sera. For serum peptides, isotop...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Testosterone measurement by isotope-dilution liquid chromatography-tandem mass spectrometry: validation of a method for routine clinical practice.

BACKGROUND Immunoassay is unsatisfactory for measuring the testosterone concentrations typically found in women. Bench-top tandem mass spectrometers are a viable alternative technology for measurements in the clinical laboratory. METHODS We used stable-isotope dilution liquid chromatography-tandem mass spectrometry (ID/LC-MS/MS) to measure testosterone in plasma and serum. The sample volume w...

متن کامل

Pilot study for the standardization of insulin immunoassays with isotope dilution liquid chromatography/tandem mass spectrometry.

BACKGROUND An international working group convened by the American Diabetes Association (ADA) called for a reference measurement procedure for use in a trueness-based standardization project of insulin immunoassays. In view of this demand, we conducted a pilot study to investigate the feasibility of such a standardization project with our isotope dilution-liquid chromatography/tandem mass spect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical biochemistry

دوره 42 6  شماره 

صفحات  -