Assessment of accuracy and precision of 99 mTc

نویسنده

  • Marian J. Surma
چکیده

BACKGROUND: The aim of the present study was the assessment of the accuracy and precision of our own simplified method for the determination of 99mTc-HEPIDA liver clearance. MATERIAL AND METHODS: It has been assumed that archived results of plasma clearance (ClPl) and hepatic (ClHp), determined by means of multisample methods, could be legitimately used as a reference standard. The accuracy and precision of the simplified method was assessed by means of a Monte Carlo method alternatively utilizing three blood sampling times (T) of 68, 75 and 83 minutes post i.v. administration of 99mTc-HEPIDA. The corresponding alternative three urine voiding times (Y) were: 75, 80, and 95 min p.i. The analysed model was created accepting values of ClPl and ClHp, of administered activity Ap and parameters of biexponential function, describing the concentration C(t) decrease of the radiopharmaceutical (RF) in plasma during time as real values. Using the function C(t) for each individual, the plasma concenAssessment of accuracy and precision of 99mTc-HEPIDA clearances determined by means of a simplified method Correspondence to: Marian J. Surma Department of Nuclear Medicine, Medical University of Łódź ul. Czechosłowacka 8–10, 92–216 Łódź, Poland Tel.: (+48 +42) 678 36 84, fax: (+48 +42) 679 17 80 e-mail: [email protected] trations of RF at three sampling times, urinary clearance (ClPl – ClHp), and voided activity (AUr(Y)) were calculated. Simulated random errors were added to the assumed blood sampling times T and to voiding time Y. To the activity Ap and AUr(Y), and RF plasma concentrations random errors were added, assuming normal distribution with relative SD from 0 to 5% and then clearance values were computed. For each process there were 5000 repeated simulated determinations. The accuracy of the simplified methods was assessed by comparing mean values of simulated clearance computations with the reference. Comparison of standard deviations with mean uncertainties enabled us to gain insight into the degree of agreement of the estimator of relative uncertainty with the coefficient of variation as a measure of precision. RESULTS: There were strong correlations between the reference clearance values and the mean values of determinations by means of the simplified procedure (r > 0.93). The correlations were practically insensitive to the uncertainty of pipetting. The lines of regression differed slightly from the lines of identity, giving an indication that there was a systematic error involved; it amounted to +4 ml/min at ClPl = 60 ml/min and to –7 ml/min for ClPl of 370 ml/min. For ClHp a bias of +6 ml/min was found for a clearance value of 16 ml/min and –13 ml/min at ClHp > 300 ml/min. At uncertainty of pipetting of 2%, a precision of 6–7% was found for ClPl of 300 ml/min. For ClPl of 200 and 150 ml/min the corresponding precisions were 7–8% and 10%, respectively. For ClHp of 200, 150 and 100 ml/min the corresponding precisions were 10, 12 and 17%, respectively. These precisions are 5 percent worse than those that were obtained from determinations by means of multisampling procedures.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE MUTATIONS OF RET PROTO-ONCOGENE IN MEDULLARY THYROID CARCINOMAS IN IRAN

MeduIIary thyroid carcinoma (MTC) occurs both sporadically and in the autosomal dominantly inherited multiple endocrine neoplasia (MEN) type 2 syndromes. The distinction between true sporadic MTC and a new mutation familial case is important for future clinical management of both the patient and family. The susceptibility gene for hereditary MTC is the RET proto-oncogene. DNA analysis for g...

متن کامل

Developing a Method for Increasing Accuracy and Precision in Measurement System Analysis: A Fuzzy Approach

Measurement systems analysis (MSA) has been applied in different aspect of industrial assessments to evaluate various types of quantitative and qualitative measures. Qualification of a measurement system depends on two important features: accuracy and precision. Since the capability of each quality system is severely related to the capability of its measurement system, the weakness of the two...

متن کامل

Estimation of glomerular filtration rate using serum cystatin C in overweight and obese subjects.

BACKGROUND Obesity and overweight are strong independent risk factors for chronic kidney disease (CKD). Using serum creatinine-based estimated glomerular filtration rate (eGFR) equations in these subjects may be inaccurate. On the other hand, cystatin C-based eGFR equations may overestimate CKD prevalence as recent findings suggest an association of cystatin C with obesity. The objective of thi...

متن کامل

Evaluation of Accuracy, Precision and Agreement of Five Hba1c Measurement Methods with HPLC Reference Method

ABSTRACT         Background and Objective: The current challenge of diabetes mellitus is to prevent its complications. These complications are directly associated with hyperglycemia in diabetics. The HbA1c measurement is essential for long-term glycemic control. Synchronization of HbA1c measurement is important in order to avoid discrepancies between resu...

متن کامل

Evaluation of accuracy, precision and consensus of four laboratory glucose measurement kits with reference method

Abstract         Background and Objective: According to recent changes in diagnostic criteria for diabetes, the harmonization of results obtained from various methods and systems by considering their accuracy and precision is essential. This study aimed to evaluate the accuracy, precision and consensus of some routine laboratory glucose kits in co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009