Correlation Between Doppler Echocardiography and Right Heart Catheterization Derived Pulmonary Artery Pressures: Impact of Right Atrial Pressures.

نویسندگان

  • Ikram Ahmed
  • Muhammad Masudul Hassan Nuri
  • Ahmad Nasiruddin Zakariyya
  • Syed Mashud Ahmad
  • Mobasher Ahmed
چکیده

OBJECTIVE To evaluate the correlation between Doppler echocardiography (DE) and right heart catheterization (RHC) derived pulmonary artery pressures and to assess the impact of right atrial (RA) pressures on this correlation. STUDY DESIGN Cross-sectional analytical study. PLACE AND DURATION OF STUDY Cardiology Department, Tahir Heart Institute, Chenab Nagar, from June 2013 to December 2014. METHODOLOGY All patients undergoing RHC were included. Relevant data were collected from hospital database. Continuous variables were expressed as the mean and SD or as the median and interquartile range where the distributions were skewed. Pearson correlation coefficient and Bland-Altman method were used to correlate DE derived right ventricular systolic pressure (RVSP) and RHC derived systolic pulmonary artery pressures (sPAP). Adjusted RVSP was calculated by replacing default value of RA pressure (10 mmHg) with RHC derived mean RA pressure. Receiver operating characteristic curve (ROC) was used to identify the best cut-off value of RVSP in predicting pulmonary hypertension. RESULTS Fifty-one patients completed the study protocol. Mean age of study population was 45.22 ±15.25 years with male to female ratio of 1.47:1. Median error was 13 mmHg (7 to 20). Pearson correlation coefficient (r) between RVSP and sPAP was 0.72. Bland-Altman method of correlation showed bias of +4.43 mmHg with 95% limits of agreement ranging from -34.61 to +43.47. Using ROC curve, the best cut-off value of RVSP was greater than 52 mmHg with accuracy of 75% (sensitivity: 81%, specificity: 69%) in predicting pulmonary hypertension. Adjusted RVSP showed only little improvement in correlation (r = 0.75), adjusted error (13.65 ±13.05) and diagnostic accuracy (79%). CONCLUSION Doppler echocardiography can frequently overestimate pulmonary artery pressures. Though correctly estimated RA pressure may improve this correlation, yet its contribution is only minimal.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Noninvasive Alternative to Swan-Ganz Catheter

Background—Although several studies have demonstrated a good correlation between Doppler echocardiographic and invasive measurements of single hemodynamic variables, the accuracy of echocardiography in providing a comprehensive assessment in individual patients has not been validated. The aim of this study was to assess the accuracy and clinical applicability of Doppler echocardiography in dete...

متن کامل

Comparison of Doppler derived haemodynamic variables and simultaneous high fidelity pressure measurements in severe pulmonary hypertension.

OBJECTIVE To assess relations between right ventricular pressure measured with a high fidelity transducer tipped catheter and the characteristics of tricuspid regurgitation recorded with Doppler echocardiography. DESIGN A prospective non-randomised study of patients with severe pulmonary hypertension referred for consideration of lung transplantation. SETTING A tertiary referral centre for ...

متن کامل

Hemodynamics of the Mueller maneuver in man: right and left heart micromanometry and Doppler echocardiography.

Ten subjects with normal hemodynamics were studied during elective cardiac catheterization with right and left heart multisensor micromanometry to assess hemodynamic responses to the Mueller maneuver. Simultaneous right and left circulatory hemodynamics and left ventricular, pulmonary arterial, and aortic pressures were recorded, in addition to pulmonary arterial and aortic flow velocities. Ste...

متن کامل

Echocardiographic Evaluation of Hemodynamics in Patients With Systolic Heart Failure Supported by a Continuous-Flow LVAD.

BACKGROUND Hemodynamics assessment is important for detecting and treating post-implant residual heart failure, but its accuracy is unverified in patients with continuous-flow left ventricular assist devices (CF-LVADs). OBJECTIVES We determined whether Doppler and 2-dimensional transthoracic echocardiography reliably assess hemodynamics in patients supported with CF-LVADs. METHODS Simultane...

متن کامل

Serial noninvasive assessment of progressive pulmonary hypertension in a rat model.

Current methods used to investigate pulmonary hypertension in rat models of the disease allow for only one to two measurements of pulmonary artery (PA) pressure in the life of a rat. We investigated whether transthoracic echocardiography can be used to assess the progression of pulmonary hypertension in rats at multiple time points. Serial echocardiographic measurements were performed over a 6-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the College of Physicians and Surgeons--Pakistan : JCPSP

دوره 26 4  شماره 

صفحات  -

تاریخ انتشار 2016