Are three sputum acid-fast bacillus smears necessary for discontinuing tuberculosis isolation?

نویسندگان

  • Philip Mathew
  • Yen-Hong Kuo
  • Bindu Vazirani
  • Robert H K Eng
  • Melvin P Weinstein
چکیده

To evaluate the efficacy of three sputum acid-fast bacillus (AFB) smears to rule out pulmonary tuberculosis, sputum AFB smear and culture results were analyzed at two university-affiliated teaching hospitals. The negative predictive value of the smear increased by only 0.2% on days 2 and 3 each, indicating that in low-prevalence populations, there is limited value in requiring three negative sputum AFB smears before discontinuing tuberculosis isolation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors influencing time to sputum conversion among patients with smear-positive pulmonary tuberculosis.

For hospitalized patients with smear-positive pulmonary or laryngeal tuberculosis, the Centers for Disease Control and Prevention recommends that three consecutive sputum samples be negative for acid-fast bacilli (AFB) before respiratory isolation is discontinued. Limited data are available to predict the length of time to obtain three negative sputum smears and cultures and to determine factor...

متن کامل

Revised Device Labeling for the Cepheid Xpert MTB/RIF Assay for Detecting Mycobacterium tuberculosis

The Food and Drug Administration (FDA) has cleared the Xpert MTB/RIF Assay (Cepheid; Sunnyvale, California) with an expanded intended use that includes testing of either one or two sputum specimens as an alternative to examination of serial acid-fast stained sputum smears to aid in the decision of whether continued airborne infection isolation (AII) is warranted for patients with suspected pulm...

متن کامل

Phenol ammonium sulphate basic fuchsin staining of sputum in pot for the detection of acid-fast bacilli.

BACKGROUND & OBJECTIVES Improper practices of making direct smears of sputum for detection of acid-fast bacilli (AFB) and of disposing sputum cups are hazardous. The present study was undertaken with the objective to stain sputum samples in their containers by 'phenol (10%) ammonium sulphate (4%) basic fuchsin (2%) solution' and to decolourize and counterstain their smears for detection of AFB-...

متن کامل

Lot quality assurance sampling of sputum acid-fast bacillus smears for assessing sputum smear microscopy centers.

Assessment of 12 microscopy centers in a tuberculosis unit by blinded checking of eight sputum smears selected by using a lot quality assurance sampling (LQAS) method and by unblinded checking of all positive and five negative slides, among the slides examined in a month in a microscopy centre, revealed that the LQAS method can be implemented in the field to monitor the performance of acid-fast...

متن کامل

Relationship between CT Findings of Pulmonary Tuberculosis and Acid-Fast Bacilli Sputum Smears

Background and purpose: Computed tomography (CT) scan is of great help in confirming the diagnosis of tuberculosis (TB) before the sputum test result. The purpose of this study was to investigate the relationship between pulmonary involvement patterns in CT scans of TB patients with positive sputum smears. Materials and methods: This retrospective descriptive-analytical study was conducted usi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 40 9  شماره 

صفحات  -

تاریخ انتشار 2002