Diagnostic Accuracy Assessment of Immunochromatographic Tests for the Rapid Detection of Antibodies against Orientia tsutsugamushi Using Paired Acute and Convalescent Specimens
نویسندگان
چکیده
We assessed the diagnostic accuracy of two immunochromatographic tests (ICTs), the Access Bio CareStart Scrub Typhus test (Somerset, NJ) (IgM), and the SD BIOLINE Tsutsugamushi test (Kyonggi-do, Republic of Korea) (IgG, IgM, or IgA) compared with indirect immunofluorescence assay (IFA) and real-time PCR results as reference tests using 86 paired acute and convalescent specimens from febrile patients. The sensitivity and specificity of the CareStart test were 23.3% (95% confidence interval [CI]: 11.8-38.6) and 81.4% (95% CI: 66.6-91.6), respectively, for acute specimens and 32.6% (95% CI: 19.1-48.5) and 79.1% (95% CI: 64.0-90.0), respectively, for convalescent specimens. For the SD BIOLINE test, sensitivity and specificity were 20.9% (95% CI: 10.0-36.0) and 74.4% (95% CI: 58.8-86.5), respectively, for acute specimens and 76.7% (95% CI: 61.4-88.2) and 76.7% (95% CI: 61.4-88.2), respectively, for convalescent specimens. The poor sensitivity obtained for both ICTs during this study when performed on acute specimens highlights the difficulties in prompt diagnosis of scrub typhus.
منابع مشابه
Accuracy of Rapid IgM-Based Immunochromatographic and Immunoblot Assays for Diagnosis of Acute Scrub Typhus and Murine Typhus Infections in Laos
We studied the diagnostic accuracy of a rapid immunochromatographic test (ICT) for detection of IgM against scrub typhus (ST ICT) and an immunoblot test for the detection of IgM against murine typhus (MT IBT) by using admission serum samples from 1,030 febrile patients in Laos. Sensitivity and specificity for the ST ICT determined by using the diagnostic criteria of a four-fold increase in IgM ...
متن کاملAccuracy of AccessBio Immunoglobulin M and Total Antibody Rapid Immunochromatographic Assays for the Diagnosis of Acute Scrub Typhus Infection.
Using archived samples, we assessed the diagnostic capacity of a rapid immunochromatographic test (ICT) for the detection of Orientia tsutsugamushi IgM and total antibodies to aid with the diagnosis of acute scrub typhus infection in febrile patients in Laos. The sensitivity and the specificity of the ICT for the detection of IgM were 96.8% (121/125 samples; 95% confidence interval [CI], 92.1 t...
متن کاملImprovement of the Diagnostic Sensitivity of Scrub Typhus Using a Mixture of Recombinant Antigens Derived from Orientia tsutsugamushi Serotypes
Diagnosis of scrub typhus is difficult because its symptoms are very similar to other acute febrile illnesses, such as leptospirosis, murine typhus, and other viral hemorrhagic fevers. To differentiate scrub typhus from other acute febrile diseases, a rapid and reliable serological diagnosis is important. We have developed a chimeric recombinant antigen cr56 and two other recombinant antigens, ...
متن کاملOrientia tsutsugamushi in Eschars from Scrub Typhus Patients
To verify the value of eschars for the diagnosis of scrub typhus and to characterize genotypes of Orientia tsutsugamushi in patients, we examined eschars and blood specimens of 7 patients from Shandong Province, People's Republic of China, for O. tsutsugamushi by polymerase chain reaction targeting the Sta56 gene. All 7 eschars and acute-phase blood samples were positive, while no specific DNA ...
متن کاملDevelopment and evaluation of a latex agglutination test for the rapid diagnosis of scrub typhus.
The purpose of this research was to develop a simple and rapid diagnostic test for scrub typhus using a latex agglutination test (LAT) to detect antibodies against Orientia tsutsugamushi. Five strains of O. tsutsugamushi were propagated in L929 cells. The rickettsiae were purified and concentrated with percoll density gradient centrifugation. A suitable concentration of O. tsutsugamushi soluble...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 93 شماره
صفحات -
تاریخ انتشار 2015