Hindrance of solute diffusion within membranes as measured with microporous membranes of known pore geometry.
نویسندگان
چکیده
I. Mica sheets were made into membranes by a process of bombardment with fission fragments from a U 235 source and subsequent etching with hydrofluoric acid. Pores formed by this process were essentially straight through the membrane, extremely uniform in size and elliptical in cross-section. On eight of these membranes, with pore radii ranging from 45 to 300 A, air flow, water flow, and diffusion rates for a graded series of 7 solutes were measured. From measurements of the diffusion rate of mostly non-electrolytes, with radii between 2.5 and 22. 5 2~, the true hindrance effect on diffusion within pores was determined. 2. Restriction of diffusion for even relatively small solutes is a very significant effect and can be adequately described by the Renkin equation ~ m / ~ o = (I--Rs/Rp) ~ × (1--2.1o4 Rs /Rp + 2.09 (Rs/Rp)3--o.95 (Rs/Rp) ~) for membranes which have welldefined, straight through pores, where ~ m / ~ o is the ratio of solute diffusivity in the membrane to that in free solution, and Rs/R~ is the ratio of solute radius to pore radius. An approximation to the Renkin equation, ~m/~0 = ( I -Rs /R~) 4, which is much simpler to use, correlates as well with the data in the range o < Rs /Rp ~ 0.2. 3. Water flow under small pressure drops is well described by the assumption of Poiseuille flow for this range of pore diameters, and therefore no effects due to "anomalous" water were apparent. 4. In most membrane operations there is a considerable resistance to diffusion due to the presence of a liquid film boundary layer along the surface of the membrane. This boundary layer resistance was not inversely proportional to the solute diffusivity as has often been assumed in the "unstirred layer" theory, but instead was found under these experimental conditions to be proportional to the --0.6 power of the solute diffusivity. 5. Boundary layer diffusion resistances were obtained by two independent methods: an electrochemical polarographic method and a membrane substitution method using membranes of known permeability to calibrate the diffusion cell. 6. Heteroporous membranes do not differ from isoporous membranes very much in regard to the relative hindrance of solute molecules, as long as the ratio of
منابع مشابه
Evaluation of Vapor Deposition Techniques for Membrane Pore Size Modification
The suitability of three vapor deposition techniques for pore size modification was evaluated using polycarbonate track etched membranes as model supports. A feature scale model was employed to predict the pore geometry after modification and the resulting pure water flux. Physical vapor deposition (PVD) and pulsed plasma-enhanced chemical vapor deposition (PECVD), naturally, form asymmetric na...
متن کاملCorrelating Physicochemical Properties of Commercial Membranes with CO2 Absorption Performance in Gas-Liquid Membrane Contactor
The gas-liquid membrane contactor (GLMC) is a promising alternative gas absorption/desorption configuration for effective carbon dioxide (CO2 ) capture. The physicochemical properties of membranes may synergistically affect GLMC performances, especially during the long-term operations. In this work, commercial polypropylene (PP) and polyvinylidene fluoride (PVDF) hollow fiber (HF) membranes wer...
متن کاملNanocomposite Ultrafiltration Membranes Incorporated with Zeolite and Carbon Nanotubes for Enhanced Water Separation
The objective of this work is to develop a new class of nanocomposite ultrafiltration (UF) membranes with excellent solute rejection rate and superior water flux using zeolitic imidazolate framework-8 (ZIF-8) and multi-walled carbon nanotubes (MWCNTs). The effect of ZIF-8 and MWCNTs loadings on the properties of polyvinyldifluoride (PVDF)-based membrane were investigated by introducing respecti...
متن کاملCharacterization of Commercial Ceramic and Hybrid Membranes Using Gas Permeation and Permporometry Tests
The gas separation performance of commercial ceramic Titania and hybrid silica (HybSi®) membranes was assessed using the gas permeation and permporometry methods. Results indicated that the HybSi® membranes have a hybrid surface containing regions covered by a polymeric matrix and others with inorganic pores. These membranes have high H2 selectivity, which incre...
متن کاملEffects of Macromolecule Concentration and Charge
A theoretical and experimental investigation has been conducted to study the untrafiltration of macromolecules through semipermeable membranes. A hydrodynamic model for the convection of rigid spherical solutes through cylindrical pores has been developed to examine the effects of solute concentration and charge on solute rejection by membrane pores. An experimental program to test the theoreti...