In vivo MR-angiography for the assessment of aortic aneurysms in an experimental mouse model on a clinical MRI scanner: Comparison with high-frequency ultrasound and histology
نویسندگان
چکیده
BACKGROUND MR-angiography currently represents one of the clinical reference-standards for the assessment of aortic-dimensions. For experimental research in mice, dedicated preclinical high-field MRI scanners are used in most studies. This type of MRI scanner is not available in most institutions. The aim of this study was to evaluate the potential of MR-angiography performed on a clinical MR scanner for the assessment of aortic aneurysms in an experimental mouse model, compared to a preclinical high-resolution ultrasound imaging system and histopathology. METHODS All in vivo MR imaging was performed with a clinical 3T MRI system (Philips Achieva) equipped with a clinical gradient system in combination with a single-loop surface-coil (47 mm). All MR sequences were based on clinically used sequences. For ultrasound, a dedicated preclinical high-resolution system (30 MHz linear transducer, Vevo770, VisualSonics) was used. All imaging was performed with an ApoE knockout mouse-model for aortic aneurysms. Histopathology was performed as reference-standard at all stages of aneurysm development. RESULTS MR-angiography on a clinical 3T system enabled the clear visualization of the aortic lumen and aneurysmal dilation at different stages of aneurysm development. A close correlation (R2 = 0.98; p < 0.001) with histological area measurements was found. Additionally, a good agreement between MR and ultrasound area measurements in systole (R2 = 0.91; p < 0.001) and diastole (R2 = 0.94; p < 0.001) were measured. Regarding interobserver reproducibility, MRI measurements yielded a smaller 95% confidence interval and a closer interreader correlation compared to ultrasound measurements (-0.37-0.46; R2 = 0.97 vs. -0.78-0.88; R2 = 0.87). CONCLUSION This study demonstrates that MR-angiography, performed on a clinical 3T MR scanner, enables the reliable detection and quantification of the aortic dilatation at different stages of aneurysm development in an experimental mouse model.
منابع مشابه
Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)
Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...
متن کاملDuctal carcinoma in situ: magnetic resonance and ultrasound imaging in mouse models of breast cancer
The earliest stage of breast cancer, ductal carcinoma in situ (DCIS), is a remarkably heterogeneous disease with diverse molecular and prognostic subtypes. Mouse models of breast cancer offer an effective experimental framework in which to investigate DCIS, and biomedical imaging can provide potential insights into the biology of these models. In this study, we develop a high resolution, multi-...
متن کاملComparison the treatment effects between simultaneous dual frequency and single frequency irradiation of ultrasound in a murine model of breast adenocarcinoma
Introduction: Transient cavitations induced by low frequency irradiation of ultrasound can be used to treat tumors. Previous studies in in-vitro experiments have shown that induced cavitation by dual or multiple frequencies of ultrasound is greater than induced cavitation by single frequency irradiation. In this study, we compared and evaluated the treatment effects of dual frequency irradiatio...
متن کاملHigh-resolution intravascular magnetic resonance quantification of atherosclerotic plaque at 3T
BACKGROUND The thickness of fibrous caps (FCT) of atherosclerotic lesions is a critical factor affecting plaque vulnerability to rupture. This study tests whether 3 Tesla high-resolution intravascular cardiovascular magnetic resonance (CMR) employing tiny loopless detectors can identify lesions and accurately measure FCT in human arterial specimens, and whether such an approach is feasible in v...
متن کاملIn vivo serial assessment of aortic aneurysm formation in apolipoprotein E-deficient mice via MRI.
BACKGROUND Hyperlipidimic mice administered angiotensin II have been used for the study of abdominal aortic aneurysms (AAAs). The purpose of this study was to examine the use of MRI for studying AAA development and for examining the effects of pharmacological intervention on AAA development in the apolipoprotein E-deficient mouse. METHODS AND RESULTS Suprarenal aortic aneurysms were generated...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2017