Model Systems for the Study of Integrative Physiology: The Rebirth of Translational Biology Use of the hyperinsulinemic euglycemic clamp to assess insulin sensitivity in guinea pigs: dose response, partitioned glucose metabolism, and species comparisons

نویسندگان

  • Dane M. Horton
  • David A. Saint
  • Julie A. Owens
  • Kathryn L. Gatford
  • Karen L. Kind
چکیده

Horton DM, Saint DA, Owens JA, Gatford KL, Kind KL. Use of the hyperinsulinemic euglycemic clamp to assess insulin sensitivity in guinea pigs: dose response, partitioned glucose metabolism, and species comparisons. Am J Physiol Regul Integr Comp Physiol 313: R19–R28, 2017. First published April 24, 2017; doi:10.1152/ajpregu.00028.2017.—The guinea pig is an alternate small animal model for the study of metabolism, including insulin sensitivity. However, only one study to date has reported the use of the hyperinsulinemic euglycemic clamp in anesthetized animals in this species, and the dose response has not been reported. We therefore characterized the doseresponse curve for whole body glucose uptake using recombinant human insulin in the adult guinea pig. Interspecies comparisons with published data showed species differences in maximal whole body responses (guinea pig human rat mouse) and the insulin concentrations at which half-maximal insulin responses occurred (guinea pig human rat mouse). In subsequent studies, we used concomitant D-[3-H]glucose infusion to characterize insulin sensitivities of whole body glucose uptake, utilization, production, storage, and glycolysis in young adult guinea pigs at human insulin doses that produced approximately half-maximal (7.5 mU·min ·kg ) and near-maximal whole body responses (30 mU·min ·kg ). Although human insulin infusion increased rates of glucose utilization (up to 68%) and storage and, at high concentrations, increased rates of glycolysis in females, glucose production was only partially suppressed (~23%), even at high insulin doses. Fasting glucose, metabolic clearance of insulin, and rates of glucose utilization, storage, and production during insulin stimulation were higher in female than in male guinea pigs (P 0.05), but insulin sensitivity of these and whole body glucose uptake did not differ between sexes. This study establishes a method for measuring partitioned glucose metabolism in chronically catheterized conscious guinea pigs, allowing studies of regulation of insulin sensitivity in this species.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of the hyperinsulinemic euglycemic clamp to assess insulin sensitivity in guinea pigs: dose response, partitioned glucose metabolism, and species comparisons.

The guinea pig is an alternate small animal model for the study of metabolism, including insulin sensitivity. However, only one study to date has reported the use of the hyperinsulinemic euglycemic clamp in anesthetized animals in this species, and the dose response has not been reported. We therefore characterized the dose-response curve for whole body glucose uptake using recombinant human in...

متن کامل

Comparison between surrogate indexes of insulin sensitivity and resistance and hyperinsulinemic euglycemic clamp estimates in mice.

Insulin resistance contributes to the pathophysiology of diabetes, obesity, and their cardiovascular complications. Mouse models of these human diseases are useful for gaining insight into pathophysiological mechanisms. The reference standard for measuring insulin sensitivity in both humans and animals is the euglycemic glucose clamp. Many studies have compared surrogate indexes of insulin sens...

متن کامل

Comparison of the [13C]glucose breath test to the hyperinsulinemic-euglycemic clamp when determining insulin resistance.

OBJECTIVE With increasing emphasis on the recognition of the metabolic syndrome and early type 2 diabetes, a clinically useful measure of insulin resistance is desirable. The purpose of this study was to evaluate whether an index of glucose metabolism, as measured by (13)CO(2) generation from ingested [(13)C]glucose, would correlate with indexes from the hyperinsulinemic-euglycemic clamp. RES...

متن کامل

Capparis spinosa L. aqueous extract evokes antidiabetic effect in streptozotocin-induced diabetic mice

Objective: As the aqueous extract of Capparis spinosa (CS) possess antidiabetic effect, he present study aims to reveal the possible  mechanism of action of CS in diabetic mice.Materials and Methods: Both single and repeated oral administrations of aqueous extract of CS were performed in multi-low dose streptozotocin-induced (MLDS) diabetic mice. Euglycemic hyperinsulinemic clamp was used in as...

متن کامل

Modeling hepatic insulin sensitivity during a meal: validation against the euglycemic hyperinsulinemic clamp.

Recently, we proposed a model describing the suppression of endogenous glucose production (EGP) during a meal. It assumes that EGP suppression depends on glucose concentration and its rate of change and on delayed insulin action. Hepatic insulin sensitivity (S(I)(Lmeal)) can be derived from EGP model parameters. This model was shown to adequately describe EGP profiles measured with multiple tra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017