How close does an uncemented hip stem match the final rasp position?
نویسندگان
چکیده
During total hip arthroplasty the final clinical position of the cementless CLS stem (Centerpulse) is not always identical to the position of the final rasp with which a successful trial reduction was performed. Therefore, the rasp-stem correspondence of CLS system (Centerpulse) was investigated in a laboratory study and compared to the CBC-T system (Mathys). Both systems showed an average rasp-stem mismatch below 2 mm in three orthogonal directions. It was found that this mismatch related to geometric differences at the corners between rasp and stem. The measured mismatch is not expected to have adverse clinical consequences.
منابع مشابه
Ultra-Short Versus Conventional Uncemented Stems for Hip Replacement in Octogenarians.
The aim of this study was to determine how an ultra-short anatomic uncemented stem vs a diaphyseal filling five-eighths porous coated uncemented femoral stem (conventional stem) affects the survival of primary total hip arthroplasties in octogenarians. The current study consisted of 52 patients (55 hips) in the ultra-short stem group (mean age, 85.5±5.3 years) and 61 patients (72 hips) in the d...
متن کاملPrimary stability in total hip replacement
BACKGROUND In total hip replacement (THR), it is essential to achieve a primary stability to guarantee good long-term results. A novel locking screw hip (LSH)-stem, anchored to the medial cortex of the proximal femur by 5 monocortical locking screws, was developed to overcome the shortcomings of uncemented press-fit and cemented straight stems while simultaneously achieving primary stability. T...
متن کاملUse of the G-guide for Measuring Stem Antetorsion During Total Hip Arthroplasty.
Implant positioning is one of the critical factors influencing postoperative outcomes in total hip arthroplasty (THA). Several studies have reported that the postoperative antetorsion (AT) measurement for the femoral stem inserted without navigation showed wide variability. The current authors developed a simple instrument, the Gravity-guide (G-guide), for intraoperative assessment of stem AT a...
متن کاملMid-term results of previously cemented hip arthroplasties revised with uncemented modular femoral components: a retrospective study
BACKGROUND We evaluated the mid-term results of previously cemented hip arthroplasties revised with uncemented modular femoral components. METHODS The study included 40 patients (36 females (90 %) and 4 males (10 %), mean age 67.6 years, range 39-87 years) who underwent revision of a previously cemented hip prosthesis with an uncemented modular femoral stem between 2005 and 2009. The indicati...
متن کاملChanges in Femoral Stem Geometry Reduce Intraoperative Femoral Fracture Rates in Total Hip Replacement
Intraoperative fracture rates in total hip arthroplasty (THA) have been associated with uncemented stems, anterolateral surgical approach, diagnoses other than osteoarthritis, and female gender. The purpose of this study was to investigate if changes in stem design would influence intraoperative fracture rates. 1497 THA with Bi-Metric stems were compared to 1277 THA with Echo Bi-Metric Full Pro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta orthopaedica Belgica
دوره 70 6 شماره
صفحات -
تاریخ انتشار 2004