A simple geometrical method of measuring anterior chamber dimensions.
نویسندگان
چکیده
Equations are described to derive the true anterior chamber dimensions of an eye from a photograph of its optical section. If the surface of the eye is assumed to be spherical, the three-dimensional coordinates of rays emanating from the anterior chamber to a camera can be transformed to two-dimensional coordinates on a plane, which contains rays both inside and outside of the "eye." The actual dimensions of the anterior chamber then were computed on the basis of the ray tracing over the entire corneal surface. The accuracy of the equations was checked using scales prepared from photographs of curvilinear grids inside an artificial anterior chamber. The advantages of this method are that the true anterior chamber dimensions can be measured in an eye of any corneal curvature and with any type of slit-lamp camera. It appears sufficiently accurate and convenient to be used for clinical and animal studies.
منابع مشابه
Effect of pilocarpine on visual acuity and on the dimensions of the cornea and anterior chamber.
The effect of pilocarpine on visual acuity and on the dimensions of the cornea, anterior chamber, and lens were studied in two groups of subjects. Significant changes in ocular tension, corneal curvature, anterior chamber depth, and lens anterior radius were found in a group of 55 glaucomatous eyes as a result of pilocarpine treatment, but there was no change in corneal thickness. Out of 102 gl...
متن کاملLeaf area estimation by a simple and non-destructive method
In this study, the relation between leaf area and its dimensions was estimated using a non-destructive method. This method is based on this fact that the leaf shape does not change during the growing season. In this method, leaf area during the growing season is estimated based on the dimensions of the smallest leaf in the initial stage of plant growth or at any growth stage by measuring the le...
متن کاملمقایسه قطره دیکلوفناک سدیم با قطره بتامتازون در پیشگیری از ادم سیستویید ماکولا، پس از جراحی کاتاراکت به روش خارج کپسولی با لنز گذاری
Background and purpose: Since Çystoid Macular Ëdema (ÇMË) is caused by ocular inflammation after cataract surgery. Ït’s control with suitable medication is reasonable. Âim of this study was to compare a nonsteroidal topical solution (0.1 % diclofenac) to a steroidal topical solution (0.1 % betamethasone) in preventing ÇMË after extra capsular cataract surgery. Materials and methods: Â pro...
متن کاملMeasurements of axial and peripheral anterior chamber depth: accuracy of a photographic method.
The minimum significant (p = 0.05 level) detectable change noted on measuring anterior chamber depth by a photographic method was found to be 7% either way from the mean. The minimum significant change for a peripheral chamber depth 5 mm from the optic axis was found to be 25% either way.
متن کاملNovel approach for anterior chamber angle analysis: anterior chamber angle detection with edge measurement and identification algorithm (ACADEMIA).
OBJECTIVE To describe a novel approach to measuring anterior chamber angle dimensions and configurations. METHODS Sixty-nine images were selected randomly from the ultrasound biomicroscopic image database to develop the algorithm. Thirty images were selected for further analyses. The value of each pixel of the 8-bit grayscale ultrasound biomicroscopic images was quantized into 0 (black) or 1 ...