Outcome evaluation of a zero-profile implant for anterior cervical diskectomy with fusion.
نویسندگان
چکیده
AIM Supplementing anterior cervical diskectomy and fusion (ACDF) with plates enhances stabilization, increases fusion and reduces failure rates. Zero-P implant for stand-alone anterior interbody fusion procedures of the cervical spine was recently developed to avoid complications associated with anterior cervical plates. We evaluate the outcome of its use in our patients undergoing ACDF. MATERIAL AND METHODS 84 patients were selected to undergo ACDF with Zero-P implant of whom 75 (52 male and 23 female) were followed up for 12 to 16 months (mean 14.2 months) with a total of 94 operated levels (54 single, 21 double level). Patients underwent pre- and postoperative clinical evaluation with full neurological examination, visual analogue scale (VAS), Neck Pain and Disability Scale (NPAD) and Bazaz-Yoo dysphagia index for postoperative dysphagia. Postoperative plain X-ray evaluation of fusion and implant-associated complications was done. REAULTS: All patients had significant reduction in arm and neck pain and NPAD maintained over 12 months, no implant-associated complications during follow-up, and radiological fusion by 3 months. None had dysphagia after 3 months postoperatively. CONCLUSION The Zero-P implant is a valid alternative to anterior cervical plating after ACDF with a very low incidence of postoperative dysphagia and no implant-related complications.
منابع مشابه
Outcome Evaluation of Zero-Profile Implant Compared with an Anterior Plate and Cage Used in Anterior Cervical Discectomy and Fusion: A Two-Year Follow-Up Study.
AIM To compare the clinical outcome and complications between Zero-P implant and cage with anterior plate in patients undergoing anterior cervical discectomy and fusion (ACDF). MATERIAL AND METHODS 50 patients underwent ACDF operation of which 23 patients had Zero-P implanted and 27 had cage and plate implanted. Preoperative and Post-operative clinical evaluation included Japanese Orthopaedic...
متن کاملZero-profile implant versus conventional cage-plate implant in anterior cervical discectomy and fusion for the treatment of degenerative cervical spondylosis: a meta-analysis
BACKGROUND Zero-profile implant has become more and more popular in anterior cervical discectomy and fusion (ACDF) for the treatment of degenerative cervical spondylosis. However, there was no enough evidence judging its efficiency and safety. The aim of this analysis was to evaluate the efficacy and safety of Zero-profile implant compared with conventional cage-plate (CCP) in ACDF. METHODS A...
متن کاملCervical Stand-Alone Polyetheretherketone Cage versus Zero-Profile Anchored Spacer in Single-Level Anterior Cervical Discectomy and Fusion : Minimum 2-Year Assessment of Radiographic and Clinical Outcome
OBJECTIVE We compared the clinical and radiographic outcomes of stand-alone polyetheretherketone (PEEK) cage and Zero-Profile anchored spacer (Zero-P) for single level anterior cervical discectomy and fusion (ACDF). METHODS We retrospectively reviewed 121 patients who underwent single level ACDF within 2 years (Jan 2011-Jan 2013) in a single institute. Total 50 patients were included for the ...
متن کاملAnterior cervical diskectomy and fusion for adjacent segment disease.
Between January 1996 and December 2005, a total of 1241 patients underwent anterior cervical decompression and fusion for cervical degenerative diseases in the authors' institution. Sixty-three (5.1%) patients underwent revision anterior cervical diskectomy and fusion for adjacent segment disease between October 2003 and August 2010. This series included 35 men and 28 women with a mean±SD age o...
متن کاملComparison of anterior cervical discectomy and fusion with the zero-profile implant and cage-plate implant in treating two-level degenerative cervical spondylosis
Previous studies based on small sample sizes have reported the application of the Zero-P implant (Zero-P, Synthes GmbH, Switzerland) in single anterior cervical discectomy and fusion (ACDF) surgery with excellent outcomes. However, the safety and effectiveness of two-level ACDF with Zero-P implant still remains controversial. A retrospective study was conducted to compare the clinical outcomes ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Turkish neurosurgery
دوره 22 5 شماره
صفحات -
تاریخ انتشار 2012