Four automated 25-OH total vitamin D immunoassays and commercial liquid chromatography tandem-mass spectrometry in Finnish population.

نویسندگان

  • Marja-Kaisa Koivula
  • Nina Matinlassi
  • Päivi Laitinen
  • Juha Risteli
چکیده

BACKGROUND Comparing four fully automated 25-OH-D immunoassays to a commercially available liquid chromatography-tandem mass spectrometry (LC-MS/MS) method with human serum samples from Finnish population. METHODS 400 samples were analyzed with the Liaison Total Vitamin D, the IDS-iSYS 25-Hydroxy Vitamin D, the ARCHITECT 25-OH Vitamin D, the ADVIA Centaur Vitamin D Total, and a commercially available LC-MS/MS 25-OH D (PerkinElmer) method. RESULTS The Liaison method mean value (95% confidence intervals) was 65.6 nmol/L (62.6 - 68.6); the IDS-iSYS mean was 70.3 nmol/L (67.4 - 73.1); the ARCHITECT mean was 69.0 nmol/L (65.5 - 72.5); ADVIA Centaur mean was 71.6 nmol/L (68.9 - 74.3), and the LC-MS/MS mean was 82.8 nmol/L (79.4 - 86.2). The regression coefficients (r) between the LC-MS/MS and immunoassays were 0.650 for Liaison, 0.757 for IDS-iSYS, 0.721 for ARCHITECT and 0.684 for ADVIA Centaur. With the Passing-Bablok analysis, none of the immunoassays gave results equivalent to LC-MS/MS. Two of the four automated 25-OH-vitamin D assays (IDS-iSYS, ADVIA Centaur) were overall in good clinical agreement with LC-MS/MS, even though the results obtained with all compared methods were not equivalent. CONCLUSIONS In conclusion, in routine clinical laboratory both immunoassays and LC-MS/MS are useful for measuring 25-OH-vitamin D provided that these methods are correctly standardized and especially sample pretreatment is carefully performed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison between two different automated total 25-hydroxyvitamin D immunoassay methods using liquid chromatography-tandem mass spectrometry

INTRODUCTION Total 25-hydroxyvitamin D [25(OH)D] is the most reliable indicator of vitamin D status. In this study, we compared two automated immunoassay methods, the Abbott Architect 25-OH Vitamin D assay and the Roche Cobas Vitamin D total assay, with the liquid chromatography-tandem mass spectrometry (LC-MS/MS). MATERIALS AND METHODS One hundred venous blood samples were randomly selected ...

متن کامل

Performance evaluation of two immunoassays for 25-hydroxyvitamin D

Although immunoassays in measuring 25-hydroxyvitamin D [25(OH)D] have been improved recently, relatively large differences are still seen between results of 25(OH)D measured by immunoassays and by liquid chromatography-tandem mass spectrometry (LC-MS/MS). In the present studies, we compared two immunoassays with LC-MS/MS for measuring 25(OH)D concentrations. Concentrations of 25-hydroxyvitamin ...

متن کامل

Analytical and clinical evaluation of the new Fujirebio Lumipulse®G non-competitive assay for 25(OH)-vitamin D and three immunoassays for 25(OH)D in healthy subjects, osteoporotic patients, third trimester pregnant women, healthy African subjects, hemodialyzed and intensive care patients.

BACKGROUND In this study, we provide a short analytical evaluation of the new Fujirebio Lumipulse®G non-competitive immunoassay for 25(OH)D. Clinical performance was compared with three commercial competitive automated immunoassays against a Vitamin D Standardization Program (VDSP)-traceable liquid chromatography-tandem mass spectrometry (LC-MS/MS) in six different clinically relevant populatio...

متن کامل

Accurate and reliable quantification of 25-hydroxy-vitamin D species by liquid chromatography high-resolution tandem mass spectrometry.

In general, mass spectrometric quantification of small molecules in routine laboratory testing utilizes liquid chromatography coupled to low mass resolution triple-quadrupole mass spectrometers (QQQs). Here we introduce high-resolution tandem mass spectrometry (quadrupole-Orbitrap) for the quantification of 25-hydroxy-vitamin D [25(OH)D], a marker of the vitamin D status, because the specificit...

متن کامل

Standardization of Misleading Immunoassay Based 25-Hydroxyvitamin D Levels with Liquid Chromatography Tandem-Mass Spectrometry in a Large Cohort Study

BACKGROUND The interest in vitamin D measurement has strongly increased in recent years. The best indicator for circulating vitamin D levels is 25-hydroxy-vitamin D (25(OH)D) which is often measured by different immunoassays. We demonstrate problems in comparability of measures by different immunoassays and the need for standardization in the context of a large population-based cohort study. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical laboratory

دوره 59 3-4  شماره 

صفحات  -

تاریخ انتشار 2013