Multicenter evaluation of a second-generation assay for cardiac troponin T.
نویسندگان
چکیده
We report on the evaluation of the second-generation assay for cardiac troponin T (cTnT) on the Enzymun system. This new assay is completely specific for the cardiac isoform of TnT, utilizing two cardiospecific monoclonal antibodies. The assay time is reduced to 45 min. The interassay precision shows a median CV of 5.5%; 20% interassay CV was found between 0.05 and 0.1 microg/L. The cardiosensitivity of the second-generation cTnT assay in patients with ischemic myocardial injury appears equivalent when compared with the first-generation assay. We found no falsely positive results in patients with skeletal muscle damage including multitraumas, surgery patients, and marathon runners who showed highly increased values with the unspecific first-generation assay. In Duchenne disease cTnT was still increased, but to a much lower extent. cTnT remains increased in renal failure, but to a lesser degree than with the first-generation assay. The cause of this increase remains unclear. Although a cross-reactivity of skeletal muscle TnT in the second-generation assay could be excluded by our findings, minor myocardial damage or expression of the cardiac isoform of TnT in regenerating muscles cannot be ruled out in those cases with apparently falsely increased cTnT values. The second-generation cTnT assay is a step forward in the combination of cardiosensitivity and cardiospecificity in biochemical markers for diagnosis of heart disease.
منابع مشابه
Evaluation of Troponin-T level in Neonate with Mechanical Ventilation
Introduction: Troponin- T is the best biological marker of heart injuries, that isn’t affected by sex, age, birth weight and gestational age. Myocardial damage in infancy is a risk factor eventual cardiac disease. This study carried out for cardiac evaluation of neonates with mechanical ventilation by Troponin T. Methods: This case-control study carried out on 60 infants that were admitte...
متن کاملCardiac troponin I, cardiac troponin T, and creatine kinase MB in dialysis patients without ischemic heart disease: evidence of cardiac troponin T expression in skeletal muscle.
Serum cardiac troponin T (cTnT) concentrations are frequently increased in chronic dialysis patients as measured by the first-generation ELISA immunoassay, as is creatine kinase (CK) MB mass in the absence of acute ischemic heart disease. We designed this study to compare four serum markers of myocardial injury [CK-MB mass, first-generation ELISA cTnT, second-generation Enzymun cTnT, and cardia...
متن کاملEvaluation of Innotrac Aio! Second-Generation Cardiac Troponin I Assay: The Main Characteristics for Routine Clinical Use
The availability of a simple, sensitive, and rapid test using whole blood to facilitate processing and to reduce the turnaround time could improve the management of patients presenting with chest pain. The aim of this study was an evaluation of the Innotrac Aio! second-generation cardiac troponin I (cTnI) assay. The Innotrac Aio! second-generation cTnI assay was compared with the Abbott AxSYM f...
متن کاملImproved troponin T ELISA specific for cardiac troponin T isoform: assay development and analytical and clinical validation.
The first generation of troponin T ELISA (TnT 1) can yield false-positive results in patients with severe skeletal muscle injury. Therefore, a cardiac-specific second-generation troponin T ELISA (TnT 2) was developed, in which the cross-reactive antibody 1B10 has been replaced by a high-affinity cardiac-specific antibody M11.7. No cross-reactivity of TnT 2 was observed with purified skeletal mu...
متن کاملTroponin T and I assays show decreased concentrations in heparin plasma compared with serum: lower recoveries in early than in late phases of myocardial injury.
BACKGROUND Heparinized plasma samples allow more rapid analysis than serum samples, but preliminary studies showed lower cardiac troponin T (cTnT) results in plasma. We undertook a multicenter study to characterize this effect for cTnT and cardiac troponin I (cTnI). METHODS Blood samples were collected with and without heparin at five hospitals. cTnT was measured by a "third generation" assay...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 43 10 شماره
صفحات -
تاریخ انتشار 1997