Computed Tomography from X-rays: Old 2-d Results, New 3-d Problems

نویسنده

  • KEITH MILLER
چکیده

We consider old results on 2-D computerized tomography methods and their relevance to new fully 3-D problems. We examine the 2-D filtered back-projection method (FBP)from several perspectives to better understand how it works. Based on that understanding, we question whether stable, reliable reconstruction algorithms can be found for widedetector cone-beam 3-D machines with their resulting large-slant beams. We use a numerical method of “point response function fitting” to compute convolution kernels H(u, v) (for use with back-projection) for a model slant-beam problem. These kernels exhibit disturbing growing and spreading oscillations which would greatly amplify errors in the projection data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners

Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...

متن کامل

Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography

Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...

متن کامل

Diffraction enhanced x-ray imaging.

Diffraction enhanced imaging is a new x-ray radiographic imaging modality using monochromatic x-rays from a synchrotron which produces images of thick absorbing objects that are almost completely free of scatter. They show dramatically improved contrast over standard imaging applied to the same phantom. The contrast is based not only on attenuation but also the refraction and diffraction proper...

متن کامل

Radiation Detection and Imaging 3.1 RADIAT ION IMAGING – ADVANCED IMAGING WITH X-RAYS AND NEUTRONS

Radiation detection/imaging is the key to understanding the basic mechanism underlying several physical phenomena. X-rays have been used for imaging and detection for over a century starting with medical X-ray imaging to X-ray diffraction, tomography to the recent physical techniques such as EXFAS, X-ray holography. The detectors for X-rays have evolved from film to imaging plate, CCD and flat ...

متن کامل

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004