Dan Benhamou Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury

نویسندگان

  • Thomas Geeraerts
  • Yoann Launey
  • Laurent Martin
  • Julien Pottecher
  • Bernard Vigué
  • Jacques Duranteau
  • Dan Benhamou
چکیده

T. Geeraerts (!) · Y. Launey · L. Martin · J. Pottecher · B. Vigué · J. Duranteau · D. Benhamou University of Paris-Sud, Department of Anesthesiology and Critical Care Medicine, Hospital of Bicêtre, Assistance Publique-Hôpitaux de Paris (AP-HP), Faculty of Medicine, Le Kremlin Bicêtre, 94275 Paris, France e-mail: [email protected] Tel.: +33-1-45213429 Fax: +33-1-45212875 Abstract Objective: To assess at admission to the ICU the relationship between optic nerve sheath diameter (ONSD) and intracranial pressure (ICP) and to investigate whether increased ONSD at patient admission is associated with raised ICP in the first 48 h after trauma. Design and setting: Prospective, blind, observational study in a surgical critical care unit, level 1 trauma center. Patients and participants: 31 adult patients with severe traumatic brain injury (TBI; Glasgow coma scale ≤ 8) requiring sedation and ICP monitoring, and 31 control patients without brain injury requiring sedation. Measurements and results: ONSD was measured with a 7.5-MHz linear ultrasound probe. Two TBI groups were defined on the basis of ICP profile. If ICP exceeded 20 mmHg for more than 30 min in the first 48 h (before any specific treatment), patients were considered to have high ICP; if not, they had normal ICP. The largest ONSD value (the highest value for the right and left eye) was significantly higher in high ICP patients (6.3 ± 0.6 vs. 5.1 ± 0.7 mm in normal ICP patients and 4.9 ± 0.3 mm in control patients). There was a significant relationship between the largest ONSD and ICP at admission (r = 0.68). The largest ONSD was a suitable predictor of high ICP (area under ROC curve 0.96). When ONSD was under 5.7 mm, the sensitivity and negative predictive values for high ICP were 100%. Conclusions: In the early posttraumatic period, ocular ultrasound scans may be useful for detecting high ICP after severe TBI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Brain Trauma Measurement of Optic Nerve Sheath Diameter for the Assessment of Risk of Raised Intracranial Pressure

Raised intracranial pressure (ICP) is associated with poor outcome after brain injury, but is difficult to detect without invasive devices. As a part of the central nervous system, the optic nerve is surrounded by a dural sheath, and the subarachnoid space surrounding the optic nerve is subject to the same pressure changes as the intracranial compartment. Distension of the optic nerve sheath re...

متن کامل

Ocular sonography in patients with raised intracranial pressure: the papilloedema revisited

Invasive devices are recommended for the early detection of raised intracranial pressure (ICP) after severe traumatic brain injury. Owing to contraindication or local issues, however, invasive ICP monitoring is not always possible. Moreover, a significant proportion of moderate traumatic brain injury patients (managed without invasive ICP) will develop raised ICP. Reliable noninvasive ICP techn...

متن کامل

Optic nerve sheath diameter on initial brain CT, raised intracranial pressure and mortality after severe TBI: an interesting link needing confirmation

Optic nerve sheath diameter (ONSD) enlargement on initial computed tomography (CT) scan has been found to be associated with increased mortality after severe traumatic brain injury. This could offer the possibility to detect patients with raised intracranial pressure requiring urgent therapeutic interventions and/or invasive intracranial monitoring to guide the treatment. The method to measure ...

متن کامل

A novel method of detecting raised intracranial pressure from head computed tomography using optic nerve sheath diameter

Introduction Raised intracranial pressure (ICP) can cause secondary brain injury, which is associated with severe disability and mortality [1]. Invasive ICP monitoring has been linked to increased mortality [2]. Sekhon, et al. [3] demonstrated a strong correlation between optic nerve sheath diameter (ONSD) on CT scan and ICP, with the potential to use this non-invasive method to detect raised ICP.

متن کامل

Effect of scuba-diving on optic nerve and sheath diameters

  Background :There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated.   Methods : Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one perso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012