Normal intersubject threshold variability and normal limits of the SITA SWAP and full threshold SWAP perimetric programs.

نویسندگان

  • Boel Bengtsson
  • Anders Heijl
چکیده

PURPOSE To compare intersubject variability and normal limits of threshold values between the new Swedish interactive test algorithm short wavelength automated perimetry (SITA SWAP) and the older Full Threshold SWAP programs (Carl Zeiss Meditec, Dublin, CA). METHODS Normal reduction of differential light sensitivity with age, age-corrected thresholds, intersubject variability, and normal limits of sensitivity were calculated from SITA SWAP and Full Threshold SWAP fields obtained in 53 normal subjects between 20 and 72 years of age. RESULTS Age influence on threshold sensitivity was the same with the two SWAP programs. On average, sensitivity decreased by 0.13 dB per year of age. Age-corrected normal threshold sensitivity was significantly higher (P<0.0001) for SITA SWAP than for Full Threshold SWAP. The means for a subject 45.4 years of age were 28.8 dB with SITA SWAP and 24.4 dB with Full Threshold SWAP. Intersubject variance was 22% smaller with SITA SWAP than with Full Threshold SWAP. Normal limits at the P<5% significance level were, on average, 14% narrower with SITA SWAP than with Full Threshold SWAP using Total Deviations from age-corrected normal thresholds and 11% narrower when applying Pattern Deviation, which is intended to adjust for general depression or elevation of the field. CONCLUSIONS SITA SWAP test results from normal eyes showed higher sensitivities than results from the older Full Threshold SWAP. This represents an increase of the dynamic range, which implies that more patients can be tested with SWAP. The smaller intersubject variability with SITA SWAP means narrower normal limits and may be associated with more sensitive probability maps.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new rapid threshold algorithm for short-wavelength automated perimetry.

PURPOSE To develop and test a short and reliable visual field threshold program for the early detection of glaucomatous visual field loss, by adapting the Swedish interactive test algorithm (SITA) to short-wavelength-automated-perimetry (SWAP). METHODS Computer simulations were performed to test the accuracy of several versions of SITA SWAP, and to optimize speed versus reliability. The selec...

متن کامل

Between-algorithm, between-individual differences in normal perimetric sensitivity: full threshold, FASTPAC, and SITA. Swedish Interactive Threshold algorithm.

PURPOSE To determine the between-algorithm differences in perimetric sensitivity for the Swedish Interactive Threshold algorithm (SITA) Standard, SITA Fast, FASTPAC, and Full Threshold algorithms; to determine the between-subject, between-algorithm differences in the magnitude of the normal variation in sensitivity. METHODS The sample comprised 50 normal subjects (mean age, 52.9 +/- 18.5 year...

متن کامل

A comparison of perimetric results with the Medmont and Humphrey perimeters.

BACKGROUND The Humphrey field analyser (HFA), Humphrey-Zeiss frequency doubling perimeter, and the Medmont automated perimeter (MAP) are three commonly used automated perimeters with threshold achromatic methodologies. Visual field loss may be detected earlier with strategies that target cell lines with reduced redundancy or which suffer selective damage. METHOD To compare these three perimet...

متن کامل

Sensitivity to Glaucomatous Visual Field Loss in Full Threshold, Sita Standard, and Sita Fast Tests

Using a newly collected normal database of visual fields obtained with the Swedish Interaction Threshold Algorithm-Standard (SITA-S), SITA Fast, and Full Threshold Programs, inter-subject variability and significance limits for deviation of threshold values were calculated and compared. Average inter-subject variance was 69% smaller with SITA-S and 59% smaller with SITA Fast compared with Full ...

متن کامل

Statistical aspects of the normal visual field in short-wavelength automated perimetry.

PURPOSE To determine the intraindividual and interindividual characteristics of normal sensitivity derived by short-wavelength automated perimetry (SWAP) as a function of threshold algorithm. To determine also the influence of ocular media absorption on the magnitude of the interindividual variation in normal sensitivity, and hence the confidence limits, derived by SWAP. METHODS The sample co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 44 11  شماره 

صفحات  -

تاریخ انتشار 2003