Dimensional measurement accuracy of recent polyether and addition silicone monophase impression materials after immersion in various disinfectants : An in vitro study

نویسندگان

  • Rupal J. Shah
  • Dipti S. Shah
  • Shilpa Duseja
چکیده

Introduction: The aim of this study was to evaluate and compare the long-term dimensional measurement accuracy of recent polyether and addition silicone monophase impression materials after their immersion in three disinfectants (dual phenol, 2% glutaraldehyde and 0.5% sodium hypochlorite) for 10 minutes and 1 hour. Methodology: Two standardized stainless steel dies were prepared (ADA specification No.19) for making impressions with monophase addition silicone (Aquasil Ultra Monophase) and polyether (Impregum Soft) impression materials. A total of 140 impressions (70 with addition silicone and 70 with polyether) were made. Ten impressions of each material were allotted to each of the seven treatment groups: (1) No disinfectant immersion (2) Immersion in dual phenol for 10-minutes (3) Immersion in 2% glutaraldehyde for 10-minutes (4) Immersion in 0.5% sodium hypochlorite (NaOCl) for 10-minutes (5) Immersion in dual phenol for 1-hour (6) Immersion in 2% glutaraldehyde for 1-hour and (7) Immersion in NaOCl for 1-hour. Dimensional stability was evaluated after 24-hours, 1-week, 2-weeks and 4-weeks storage. Statistical analyses were performed using Separate 2-factor repeated measure ANOVAs and Bonferonni post hoc tests (α = 0.05). Results: The expansion produced by disinfection in monophase addition silicone was found to be statistically insignificant (P>0.05) as compared to non-disinfected specimens. However, all disinfection protocols resulted in statistically significant (P≤0.05) expansion of polyether in comparison to non-disinfected impressions. There was significant shrinkage of both impression materials over time at room temperature. The dimensional changes at 4 weeks storage were found to be more than 0.5%, which is unacceptable in accordance with ADA guidelines. However, mean percent dimensional changes were found to be satisfactory after 2 weeks storage period. Conclusion: The dimensional measurement accuracy of both disinfected and non-disinfected monophase addition silicone and polyether is affected by storage. However, all measurements met the ADA criteria even at 2 weeks storage. Irrespective of disinfection, the pouring of impressions after 4 weeks of storage is not advisable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Evaluation of Dimensional Accuracy of Elastomeric Impression Materials when Treated with Autoclave, Microwave, and Chemical Disinfection

BACKGROUND Impression materials during impression procedure often get infected with various infectious diseases. Hence, disinfection of impression materials with various disinfectants is advised to protect the dental team. Disinfection can alter the dimensional accuracy of impression materials. The present study was aimed to evaluate the dimensional accuracy of elastomeric impression materials ...

متن کامل

Comparative Analysis of Dimensional Accuracy of Two Types of Silicone Impression Materials: Optosil and Elite-HD

Statement of the Problem: Understanding about impression materials, their properties, uses and manipulation can guide operators towards having more successful restorations. Purpose: The aim of this in vitro study was to compare the accuracy of a condensation silicone impression material, Optosil, and an addition poly siloxane impression material, Elite-HD. Materials and Method: A laboratory mod...

متن کامل

The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials.

The aim of this study was to determine the effect of immersion disinfection procedures on the dimensional stability of two elastomeric impression materials. Impressions of a stainless steel die were made with polyether (PE) and with addition-polymerized silicone rubber (PVS). The test specimens underwent disinfection treatment by immersion in two commercially available solutions containing quat...

متن کامل

Effect of Three Disinfectants on Dimensional Changes of Different Impression Materials

Background and Aim: Disinfection of dental impression materials can alter their dimensional stability, which in turn can affect the accuracy of dental casts. This study aimed to determine the effect of three disinfectants on the dimensional changes of ir-reversible hydrocolloid impression materials and addition silicones. Materials and Methods: Forty alginate and 40 addition silicone impressio...

متن کامل

Dimensional accuracy of three impression materials by one-step and two-step impression techniques: An in vitro study

Introduction: An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. Methods: In this study, 20 impressions were fabricated for each Vinyl siloxane ether (Identium), condensation silicone (Speedex), and a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014