Optimization of the X-ray incidence angle in photoelectron spectrometers
نویسنده
چکیده
The interplay between the angle-dependent X-ray reflectivity, X-ray absorption and the photoelectron attenuation length in the photoelectron emission process determines the optimal X-ray incidence angle that maximizes the photoelectron signal. Calculations in the wide VUV to the hard X-ray energy range show that the optimal angle becomes more grazing with increasing energy, from a few tens of degrees at 50 eV to about one degree at 3.5 keV. This is accompanied by an intensity gain of a few tens of times, as long as the X-ray footprint on the sample stays within the analyzer field of view. This trend is fairly material-independent. The obtained results bear immediate implications for the design of (synchrotron-based) photoelectron spectrometers.
منابع مشابه
Grazing angle x-ray photoemission system for depth-dependent analysis
We have developed an x-ray photoelectron spectrometer system which combines an adjustable grazing incidence angle source with reflected beam detection. When operated about the critical angle, this combination permits a variation of the x-ray penetration depth which can be monitored by means of the reflectivity. At angles of incidence less than the critical angle, the sampling depth of the photo...
متن کاملAngle-resolved environmental X-ray photoelectron spectroscopy: a new laboratory setup for photoemission studies at pressures up to 0.4 Torr.
The paper presents the development and demonstrates the capabilities of a new laboratory-based environmental X-ray photoelectron spectroscopy system incorporating an electrostatic lens and able to acquire spectra up to 0.4 Torr. The incorporation of a two-dimensional detector provides imaging capabilities and allows the acquisition of angle-resolved data in parallel mode over an angular range o...
متن کاملHigh-resolution soft X-ray beamline ADRESS at the Swiss Light Source for resonant inelastic X-ray scattering and angle-resolved photoelectron spectroscopies
The concepts and technical realisation of the high-resolution soft X-ray beamline ADRESS operating in the energy range from 300 to 1600 eV and intended for resonant inelastic X-ray scattering (RIXS) and angle-resolved photoelectron spectroscopy (ARPES) are described. The photon source is an undulator of novel fixed-gap design where longitudinal movement of permanent magnetic arrays controls not...
متن کاملSkin layer of BiFeO(3) single crystals.
A surface layer ("skin") different from the bulk was found in single crystals of BiFeO(3). Impedance analysis and grazing incidence x-ray diffraction reveal a phase transition at T(*)∼275±5 °C that is confined within the surface of BiFeO(3). X-ray photoelectron spectroscopy and refraction-corrected x-ray diffraction as a function of incidence angle and photon wavelength indicate a reduced elect...
متن کاملScanning photoelectron microscope for nanoscale three-dimensional spatial-resolved electron spectroscopy for chemical analysis.
In order to achieve nondestructive observation of the three-dimensional spatially resolved electronic structure of solids, we have developed a scanning photoelectron microscope system with the capability of depth profiling in electron spectroscopy for chemical analysis (ESCA). We call this system 3D nano-ESCA. For focusing the x-ray, a Fresnel zone plate with a diameter of 200 μm and an outermo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 20 شماره
صفحات -
تاریخ انتشار 2013