An image-guided femoroplasty system: Development and initial cadaver studies

نویسندگان

  • Yoshito Otake
  • Mehran Armand
  • Ofri Sadowsky
  • Robert S. Armiger
  • Michael D. Kutzer
  • Simon C. Mears
  • Peter Kazanzides
  • Russell H. Taylor
چکیده

This paper describes the development and initial cadaver studies using a prototype image-guided surgery system for femoroplasty, which is a potential alternative treatment for reducing fracture risk in patients with severe osteoporosis. Our goal is to develop an integrated surgical guidance system that will allow surgeons to augment the femur using patient-specific biomechanical planning and intraoperative analysis tools. This paper focuses on the intraoperative module, which provides real-time navigation of an injection device and estimates the distribution of the injected material relative to the preoperative plan. Patient registration is performed using intensity-based 2D/3D registration of X-ray images and preoperative CT data. To co-register intraoperative X-ray images and optical tracker coordinates, we integrated a custom optically-tracked fluoroscope fiducial allowing real-time visualization of the injection device with respect to the patient's femur. During the procedure, X-ray images were acquired to estimate the 3D distribution of the injected augmentation material (e.g. bone cement). Based on the injection progress, the injection plan could be adjusted if needed to achieve optimal distribution. In phantom experiments, the average target registration error at the center of the femoral head was 1.4 mm and the rotational error was 0.8 degrees when two images were used. Three cadaveric studies demonstrated efficacy of the navigation system. Our preliminary simulation study of the 3D shape reconstruction algorithm demonstrated that the 3D distribution of the augmentation material could be estimated within 12% error from six X-ray images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-Mode C-Arm Fluoroscopy, Tomosynthesis, and Cone-Beam CT for Image-Guided Interventions: From Proof of Principle to Patient Protocols

High-performance intraoperative imaging is essential to an ever-expanding scope of therapeutic procedures ranging from tumor surgery to interventional radiology. The need for precise visualization of bony and soft-tissue structures with minimal obstruction to the therapy setup presents challenges and opportunities in the development of novel imaging technologies specifically for image-guided pr...

متن کامل

Health technology assessment of image-guided radiotherapy (IGRT): A systematic review of current evidence

Background: Image-guided radiotherapy used multiple imaging during the radiation therapy course to improve the precision and accuracy of health care provider's treatment. Objectives: This study aims to assess the safety, effectiveness and economic aspects of image-guided radiation therapy for decision-making about this technology in Iran. Methods: In this study, the most important med...

متن کامل

Intraoperative cone-beam CT for guidance of temporal bone surgery.

OBJECTIVES To describe our preclinical experience with Cone Beam CT (CBCT) in image-guided surgery of the temporal bone. STUDY DESIGN AND SETTINGS A mobile isocentric C-arm (PowerMobil, Siemens Medical Systems, Erlangen, Germany) modified to include a flat-panel detector (Varian Imaging Products, Palo Alto, CA) and a motorized orbit was developed to acquire multiple projections in rotation ab...

متن کامل

Rendering-based video-CT registration with physical constraints for image-guided endoscopic sinus surgery

We present a system for registering the coordinate frame of an endoscope to pre- or intra- operatively acquired CT data based on optimizing the similarity metric between an endoscopic image and an image predicted via rendering of CT. Our method is robust and semi-automatic because it takes account of physical constraints, specifically, collisions between the endoscope and the anatomy, to initia...

متن کامل

Stochastic rank correlation: a robust merit function for 2D/3D registration of image data obtained at different energies.

In this article, the authors evaluate a merit function for 2D/3D registration called stochastic rank correlation (SRC). SRC is characterized by the fact that differences in image intensity do not influence the registration result; it therefore combines the numerical advantages of cross correlation (CC)-type merit functions with the flexibility of mutual-information-type merit functions. The bas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010