Cavity ring-down technique and its application to the measurement of ultraslow velocities.

نویسندگان

  • K An
  • C Yang
  • R R Dasari
  • M S Feld
چکیده

We have developed a new ring-down technique that does not require a shutter to turn a probe laser on and off. With a rapid cavity scan we can measure a simple exponential cavity decay from which a cavity finesse can be found. When the cavity is scanned slowly, the cavity decay exhibits an amplitude modulation, and an analytic expression is derived for this modulation. With this new technique we measured the ultraslow relative velocity of the mirrors (of the order of micrometers per second) as well as the linewidth (,100 kHz) of the probe laser.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous measurement of quality factor and wavelength shift by phase shift microcavity ring down spectroscopy.

Optical resonant microcavities with ultra high quality factors are widely used for biosensing. Until now, the primary method of detection has been based upon tracking the resonant wavelength shift as a function of biodetection events. One of the sources of noise in all resonant-wavelength shift measurements is the noise due to intensity fluctuations of the laser source. An alternative approach ...

متن کامل

Species-Specific Sputtering Measurements with Cavity Ring-Down Spectroscopy

We report sputtering studies using cavity ring-down spectroscopy (CRDS). The high sensitivity of the technique and its non-intrusive nature make it amenable to both in situ device studies as well as basic characterization studies. We provide demonstrative measurements of sputtered particles showing the ability to determine species-specific number density and velocity. We summarize a spatial-sca...

متن کامل

Application of Molecular DNA Markers (STRs) in Molecular Diagnosis of Down Syndrome in Iran

Down syndrome is one of the most common causes of mental retardation observed in approximately 1/700 live birth. The use of two or more STR markers related to chromosome 21 facilitates the diagnosis of Down syndrome within about six hours from the collection of the samples. This is the first study has been performed in Iranian population to assess the diagnostic value of using small tandem repe...

متن کامل

Topical application of Mitomycin C in the treatment of granulation tissue after Canal Wall Down mastoidectomy

Introduction: Otorrhea and granulation tissue in Canal Wall Down mastoidectomy (CWD) is the common problem in cholesteatoma removal and leads to many discomfort for both the patient and the physician. The main objective in CWD is creating the dry cavity, so the topical antibiotic and acetic acid in variable saturations are used for this purpose. In this study we evaluate the effectiveness of to...

متن کامل

Tunable ultraslow light in vertical-cavity surface-emitting laser amplifier.

We report the experimental demonstration of tunable ultraslow light using a 1.55 um vertical-cavity surface-emitting laser (VCSEL) at room temperature. By varying the bias current around lasing threshold, we achieve tunable delay of an intensity modulated signal input. Delays up to 100 ps are measured for a broadband signal with modulation frequency of 2.8 GHz. With a VCSEL design optimized for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics letters

دوره 20 9  شماره 

صفحات  -

تاریخ انتشار 1995