Workplace alcohol testing program by combined use of ethyl glucuronide and fatty acid ethyl esters in hair.

نویسندگان

  • M Hastedt
  • S Herre
  • F Pragst
  • M Rothe
  • S Hartwig
چکیده

AIMS The applicability of fatty acid ethyl esters (FAEEs) and ethyl glucuronide (EtG) in hair in a workplace alcohol testing program was investigated. METHODS A total of 78 hair samples from employees in jobs with a high endangering potential were tested for EtG and FAEEs. In most cases excessive drinking was suspected. For 59 of these cases additional data of the traditional alcohol markers aspartate aminotransferase, alanine aminotransferase and gamma-glutamyltransferase and of the mean corpuscular volume of the erythrocytes (58 cases) were available. RESULTS By application of the cut-offs of the Consensus of the Society of Hair Testing and of a gradual system for combined interpretation of FAEEs and EtG in hair no indications of alcohol abuse were obtained in 50 cases (64%), slight indications were seen in 13 cases (17%) and clear indications in 11 cases (14%). In four cases, the results were inconclusive with strongly conflicting results of both markers, the reason for which could not be cleared. The traditional markers confirmed the hair results only partly and displayed altogether a lower portion of positive results. CONCLUSION EtG and FAEEs in hair, especially when interpreted in combination, are suitable for application in workplace alcohol testing programs. Nevertheless, the results obtained by hair analysis for alcohol markers can only be one part of a proper assessment aiming at the question whether an employee is addicted to alcohol or not.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

2014 consensus for the use of alcohol markers in hair for assessment of both abstinence and chronic excessive alcohol consumption.

1.1 The direct determination of ethanol itself in hair is not possible due to its volatility and its potential absorption from external sources. Instead, the minor ethanol metabolites ethyl glucuronide (EtG) and/or fatty acid ethyl esters (FAEEs) can be measured in hair as direct markers of alcohol consumption. 1.2 In this consensus FAEEs are defined as: ethyl myristate, ethyl palmitate, ethyl ...

متن کامل

A SPME-GC/MS procedure for the determination of fatty acid ethyl esters in hair for confirmation of abstinence test results.

Fatty acid ethyl esters (FAEE), direct metabolites of ethanol, are suitable alcohol markers that can be detected in different tissues. The determination of FAEE in hair can help to evaluate social and excessive alcohol consumption. Due to the presence of FAEE in the hair of teetotalers, proving alcohol abstinence seems to be impossible. To verify these results, an solid phase micro extraction-g...

متن کامل

Combining serum carbohydrate-deficient transferrin and hair ethyl glucuronide to provide optimal information on alcohol use.

Weykamp et al. recently reported on their efforts toward the harmonization of carbohydrate-deficient transferrin (CDT) measurements in serum (1). Alcohol biomarkers play a key role in the identification of alcohol abuse, a chronic disorder with enormous health and legal implications. CDT is a widely used biomarker for the detection of excessive alcohol use that has a high diagnostic sensitivity...

متن کامل

Direct and indirect alcohol biomarkers data collected in hair samples - multivariate data analysis and likelihood ratio interpretation perspectives

The concentration values of direct and indirect biomarkers of ethanol consumption were detected in blood (indirect) or hair (direct) samples from a pool of 125 individuals classified as either chronic (i.e. positive) and non-chronic (i.e. negative) alcohol drinkers. These experimental values formed the dataset under examination (Table 1). Indirect biomarkers included: aspartate transferase (AST...

متن کامل

Direkte Ethanolmetabolite in Blut und Urin: Relevanz in Diagnose und Therapie alkoholbezogener Störungen

Direct Ethanol Metabolites. Currently available biological state markers of alcohol intake are limited in two basic respects: (1) Their time spectra are limited to only recent intake (e.g. serum ethanol detects only use within the past several hours) or long-term, chronic intake through measurement of adverse consequences of heavy drinking on end-organ functioning (gamma glutamyl transpeptidase...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Alcohol and alcoholism

دوره 47 2  شماره 

صفحات  -

تاریخ انتشار 2012