Reliability and measurement error of active knee extension range of motion in a modified slump test position: a pilot study.

نویسندگان

  • Neil Tucker
  • Duncan Reid
  • Peter McNair
چکیده

The slump test is a tool to assess the mechanosensitivity of the neuromeningeal structures within the vertebral canal. While some studies have investigated the reliability of aspects of this test within the same day, few have assessed the reliability across days. Therefore, the purpose of this pilot study was to investigate reliability when measuring active knee extension range of motion (AROM) in a modified slump test position within trials on a single day and across days. Ten male and ten female asymptomatic subjects, ages 20-49 (mean age 30.1, SD 6.4) participated in the study. Knee extension AROM in a modified slump position with the cervical spine in a flexed position and then in an extended position was measured via three trials on two separate days. Across three trials, knee extension AROM increased significantly with a mean magnitude of 2 degrees within days for both cervical spine positions (P>0.05). The findings showed that there was no statistically significant difference in knee extension AROM measurements across days (P>0.05). The intraclass correlation coefficients for the mean of the three trials across days were 0.96 (lower limit 95% CI: 0.90) with the cervical spine flexed and 0.93 (lower limit 95% CI: 0.83) with cervical extension. Measurement error was calculated by way of the typical error and 95% limits of agreement, and visually represented in Bland and Altman plots. The typical error for the cervical flexed and extended positions averaged across trials was 2.6 degrees and 3.3 degrees , respectively. The limits of agreement were narrow, and the Bland and Altman plots also showed minimal bias in the joint angles across days with a random distribution of errors across the range of measured angles. This study demonstrated that knee extension AROM could be reliably measured across days in subjects without pathology and that the measurement error was acceptable. Implications of variability over multiple trials are discussed. The modified set-up for the test using the Kincom dynamometer and elevated thigh position may be useful to clinical researchers in determining the mechanosensitivity of the nervous system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of nonballistic active knee extension in neural slump position and static stretch techniques on hamstring flexibility.

Nonballistic, active range of motion exercises have been advocated as more effective than static stretching for increasing range of motion, yet no published data exist to support this claim. This study compared the effect of nonballistic, repetitive active knee extension movements performed in a neural slump sitting position with static stretching technique on hamstring flexibility. Forty healt...

متن کامل

Study of knee range of motion after soft tissue repair in both flexion and extension during total knee arthroplasty: a randomized clinical trial

Background: The patient's position during the recovery time after arthroplasty surgery can be a factor in reducing complications and improving patients’ condition. Therefore, this study was performed to compare the knee range of motion after soft tissue repair in both flexion and extension positions of total knee arthroplasty. Methods: This study is a double-blind clinical trial. The study pop...

متن کامل

The Reliability of Bubble Inclinometer and Tape Measure in Determining Lumbar Spine Range of Motion in Healthy Individuals and Patients

Purpose: Regarding the high prevalence of low back pain in various communities and the need to determine an appropriate treatment plan for these patients, examining their functional limitation and disability level is of utmost importance. In this regard, one of the important indicators is Lumbar range of motion. Measurement of the range of motion is a common and appropriate method for determini...

متن کامل

Knee Laxity or Loss of Knee Range of Motion after PCL Reconstruction: A Systematic Review and Meta-Analysis

Background. PCL reconstruction is a successful method for enhancing the patientchr('39')s quality of life but posterior knee laxity and knee stiffness have still occurred surgery. There is no study to evaluate knee laxity or loss of knee range of motion after surgery. Objectives. To assess the outcomes after PCL reconstruction, we: 1) evaluated the range of motion of the knee, 2) evaluated pos...

متن کامل

Effect of balance training on unstable platform with tilting, translation and combined motion on knee joint position sense in active young males

Proprioception is essential for joint function and through which individual can detect body parts movement in space. Aim of present study is to investigate effect of balance training on unstable platform with tilting, translation and combined motion on knee joint position sense in active young males. 39 healthy active male divided in to three training and control (n=9) groups. Training on unsta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of manual & manipulative therapy

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 2007