Effectiveness, safety and acceptability of Sino-implant (II) during the first year of use: results from Kenya and Pakistan.
نویسندگان
چکیده
BACKGROUND Sino-implant (II) is a two-rod subcutaneous contraceptive implant used up to 4 years, containing 150 mg of levonorgestrel. We conducted two observational studies of Sino-implant (II) to evaluate its performance in routine service delivery settings. METHODS We enrolled 1326 women age 18-44 who had Sino-implant (II) inserted at clinics in Pakistan and Kenya. Women were followed-up using either an active or passive follow-up scheme in each study. Study outcomes were: one-year cumulative pregnancy and discontinuation rates; rates of insertion and removal complications; adverse event and side effect rates; reasons for discontinuation; and implant acceptability and satisfaction with clinic services. RESULTS A total of 754 women returned for at least one follow-up visit. The overall Pearl pregnancy rate was 0.4 per 100 woman-years [95% confidence interval (CI) 0.1, 0.9] resulting from 1 confirmed post-insertion pregnancy in Kenya and 4 in Pakistan. Country-specific Pearl rates were 0.2 (95% CI 0.0, 0.9) in Kenya and 0.6 (95% CI 0.2, 1.6) in Pakistan. The total cumulative 12-month probability of removal was 7.6% (95% CI 6.1, 9.1), with country-specific removal probabilities of 3.7% in Kenya (95% CI 2.1, 5.3) and 10.8% in Pakistan (95% CI 8.5, 13.2). Four serious adverse events occurred in Kenya and none occurred in Pakistan; one SAE (an ectopic pregnancy) was possibly related to Sino-implant (II). Most women in both countries said they would recommend the implant to others. CONCLUSION The results from these studies reveal high effectiveness and favorable safety and acceptability during the first year of use of Sino-implant. IMPLICATION The favorable Sino-implant (II) findings from Kenya and Pakistan provide further evidence from disparate regions that Sino-implant (II) is safe, effective and acceptable during routine service delivery.
منابع مشابه
Rationale, design, and cohort enrolment of a prospective observational study of the clinical performance of the new contraceptive implant (Femplant) in Pakistan
INTRODUCTION The use of hormonal implants has gained positive traction in family planning programs in recent times. Compared to other popular methods, such as long-term reversible intrauterine devices, the use of hormonal implants as a family planning method has distinct advantages in terms of long-term efficiency and better user compliance and availability. This paper presents a study protocol...
متن کاملAnalysis and Forecast of Mining Accidents in Pakistan
In the mining sector, the barrier to obtain an efficient safety management system is the unavailability of future information regarding the accidents. This paper aims to use the auto-regressive integrated moving average (ARIMA) model, for the first time, to evaluate the underlying causes that affect the safety management system corresponding to the number of accidents and fatalities in the surf...
متن کاملThe clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study
The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study Dr. M. Rismanchian * - Dr. R. Birang ** * Assistant Professor of Fixed Prosthodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Assistant Professor of Periodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences....
متن کاملEvaluation of SubcutaneousRush Immunotherapy Effectiveness in Perennial Allergic Rhinitis after a Year from Treatment
Introduction: Allergen immunotherapy is an effective treatment for allergic rhinitis. Conventional immunotherapy takesat least 5 to 6 months to reach the maintenance dosage; nonetheless, rush immunotherapy accelerates to reach the maintenance dose several months earlier. However, the safety and efficacy of this treatment has not been widely investigated. The objective of the present study...
متن کاملRadiographic Comparison of Crestal Bone Loss Around Two Implant Systems with Different Surface Roughness: A Retrospective Study
Background and Aim: This retrospective study aimed to investigate the effects of surface roughness and implant body design on the amount of crestal bone loss around implant. Materials and Methods: In this retrospective study, dental records of 87 patients who received 139 implants were evaluated. The ITI group received 63 implants with moderate roughness, while the DIO group received 76 implan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Contraception
دوره 89 3 شماره
صفحات -
تاریخ انتشار 2014