A partially automated radioligand binding assay system for use in clinical and pharmaceutical research.

نویسندگان

  • B Liebl
  • T Anhäupl
  • E Haen
  • B Günster
  • M Georgieff
چکیده

Using a Tecan robotic sample processor and IBM compatible PCs we have developed a flexible, partially automated radioligand binding assay system. It handles pipetting parameters of up to 16 saturation or competition experiments at a time with up to 24 radioligand- or competitor-concentrations in a range over 4 orders of magnitude per experiment. The system provides enough flexibility so that all pipetting parameters including different tube-, rack-sizes, sample volumina and pipetting sequences may be easily adapted to the large variety of experimental requirements in binding assays. It rationalizes and increases assay throughput (up to 70% spare of working time), improves reliance and reproducibility of results. Radioactive exposure is minimized to the time preparing the radioligand working solution and transferring the sample tubes to and from the sample processor. The system has proven effective in various investigations on binding interactions, as well as in clinical studies on receptor expression under physiologic, pathological and therapeutic conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimum Conditions of Radioligand Receptor Binding Assay of Ligands of Benzodiazepine Receptors

To obtain drugs which are more selective at benzodiazepine (BZD) receptors, design and synthesis of functionally selective ligands for BZD receptors is the current strategy of our pharmaceutical chemistry department. The affinity of newly synthesized ligands is assessed by radioligand receptor binding assays. Based on our previous studies, 2-phenyl-5-oxo-7-methyl-1,3,4-oxadiazolo[a,2,3]-pyrimid...

متن کامل

Optimum Conditions of Radioligand Receptor Binding Assay of Ligands of Benzodiazepine Receptors

To obtain drugs which are more selective at benzodiazepine (BZD) receptors, design and synthesis of functionally selective ligands for BZD receptors is the current strategy of our pharmaceutical chemistry department. The affinity of newly synthesized ligands is assessed by radioligand receptor binding assays. Based on our previous studies, 2-phenyl-5-oxo-7-methyl-1,3,4-oxadiazolo[a,2,3]-pyrimid...

متن کامل

Automated continuous-flow radioimmunoassay for salivary estriol.

We have automated a radioimmunoassay for salivary estriol by using the "Southmead" continuous-flow system. The assay, based on a well-validated manual assay, involves a Sepharose-coupled antiserum and an 125I-radioligand. The antibody-bound and free radioligand fractions are separated by on-line filtration. Performance of the automated assay has been reliable during six months of regular use, a...

متن کامل

Performance characteristics of three automated immunoassays for thyroid hormones

Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...

متن کامل

Automated "Gamma-flo" radioimmunoassay of urinary cyclic AMP.

The "Gammaflow" automated assay concept of Brooker et al. (Science 194:270, 1976) has been adapted to the assay for urinary cyclic AMP in patients' samples on the now commercially available Squibb Gamma-FloTM system, a totally automated continuous-flow immunoassay instrument. The instrument aspirates the unknown sample, combines it with radioligand and specific antiserum, incubates the mixture,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of receptor research

دوره 13 1-4  شماره 

صفحات  -

تاریخ انتشار 1993