Multicenter clinical validation of an on-line monitor of dialysis adequacy.
نویسندگان
چکیده
Quantitation of hemodialysis by measuring changes in blood solute concentration requires careful timing when taking the postdialysis blood sample to avoid errors from postdialysis rebound and from recirculation of blood through the access device. It also requires complex mathematical interpretation to account for solute disequilibrium in the patient. To circumvent these problems, hemodialysis can be quantified and its adequacy assessed by direct measurement of the urea removed in the dialysate. Because total dialysate collection is impractical, an automated method was developed for measuring dialysate urea-nitrogen concentrations at frequent intervals during treatment. A multicenter clinical trial of the dialysate monitoring device, the Biostat 1000 (Baxter Healthcare Corporation, McGaw Park, IL) was conducted to validate the measurements of urea removed, the delivered dialysis dose (Kt/V), and net protein catabolism (PCR). The results were compared with a total dialysate collection in each patient. During 29 dialyses in 29 patients from three centers, the paired analysis of urea removed, as estimated by the dialysate monitor compared with the total dialysate collection, showed no significant difference (14.7 +/- 4.7 g versus 14.8 +/- 5.1 g). Similarly, measurements of Kt/V and PCR showed no significant difference (1.30 +/- 0.18 versus 1.28 +/- 0.19, respectively, for Kt/V and 42.3 +/- 15.7 g/day versus 52.2 +/- 17.4 g/day for PCR). When blood-side measurements during the same dialyses were analyzed with a single-compartment, variable-volume model of urea kinetics, Kt/V was consistently overestimated (1.49 +/- 0.29/dialysis, P < 0.001), most likely because of failure to consider urea disequilibrium. Because urea disequilibrium is difficult to quantitate during each treatment, dialysate measurements have obvious advantages. The dialysate monitor eliminated errors from dialysate bacterial contamination, simplified dialysate measurements, and proved to be a reliable method for quantifying and assuring dialysis adequacy.
منابع مشابه
Impact of Jacobson Relaxation on Dialysis Adequacy in ElderlyHemodialysis Patients
Background: Dialysis adequacy is one of the determining factors for survival in elderly patients. Improving the dialysis adequacy highly affects the remission and prognosis of old dialysis patients. Current study was conducted to evaluate the effects of Jacobson relaxation technique on dialysis adequacy in elderly people, who are under dialysis treatment. Methods: ods: This is a clinical trial...
متن کاملDialysis adequacy of chronic hemodialysis patients in Zanjan-Iran, 2016
Background: Dialysis adequacy is one of the most important factors in determining the survival rate and mortality of dialysis patients. Objectives: The aim of this study was to determine the dialysis adequacy of patients undergoing chronic hemodialysis at dialysis centers located in the province of Zanjan, located in northwest Iran. Methods: This descriptive cross-sectional study was performe...
متن کاملDepression Prevalence and Its Relationship with Dialysis Adequacy and Demographic Characteristics in Hemodialysis Patients
Background & aim: Depression is the most common psychopathological disorder among hemodialysis patients. This disorder can reduce the quality of life of patients. adequacy of dialysis and demographic characteristic can be effective factors in the prevalence of depression disorder. The aim of this study was to determine the relationship between depression and dialysis adequacy and demographic ch...
متن کاملتاثیر بولوس متناوب محلول نرمال سالین در حین همودیالیز بر کفایت دیالیز
Background and purpose: Using practical and non-invasive methods to improve the adequacy of dialysis (i.e. Kt/V) can increase the quality of life and decrease the mortality and morbidity rate in patients under hemodialysis. This study was conducted to investigate the effect of intermittent normal saline bolus on adequacy of dialysis. Materials and methods: In this randomized controlled...
متن کاملCytotoxic Glucose Degradation Products in Fluids for Peritoneal Dialysis
During the standard heat sterilization process of the lactate–buffered peritoneal dialysis solutions, glucose (an osmotic active substance) degrades to form compounds called glucose degradation products which are cytotoxic and affect the survival of the peritoneal membrane. This case presentation is based on an observation of 224 aseptic peritonitis cases of unknown etiology. For the purpose of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American Society of Nephrology : JASN
دوره 7 3 شماره
صفحات -
تاریخ انتشار 1996