The "Safe Zone" Technique Improves Suture Placement and Accuracy During Arthroscopic Remplissage.

نویسندگان

  • Grant H Garcia
  • Ryan M Degen
  • Joseph N Liu
  • Cynthia A Kahlenberg
  • Daniel J Hurwit
  • Joshua S Dines
چکیده

In response to recent concerns about the accuracy of suture passage during arthroscopic remplissage, this study was conducted to determine whether a previously described "safe zone" technique can improve the accuracy of suture passage. A recommended safe zone technique was used for arthroscopic remplissage on 6 cadaveric specimens. The safe zone was described as a region at least 1 cm lateral and no greater than 3 cm distal to the posterolateral acromion. Results were compared with a control group of 6 specimens for which the safe zone technique was not used. For each group, 24 suture passes were performed. In the safe zone group, 83.3% (20 of 24) of sutures passed through the infraspinatus tendon. This was a significant improvement compared with the control group, in which only 25% (6 of 24) of sutures pierced the infraspinatus tendon (P<.01). In the safe zone group, 4.2% (1 of 24) of attempted suture passes were placed through the muscle or musculotendinous junction compared with 75% (18 of 24) in the control group (P<.01). Prevention of overmedialization improved significantly with the safe zone technique. In the safe zone group, both anchors had significantly more lateral (6 to 10 mm) suture passage compared with the control group (P<.01). The safe zone technique also showed greater precision of suture passes, and overall precision (SD) improved in 75% of passes. The safe zone technique significantly improved the accuracy of suture penetration into the infraspinatus tendon during arthroscopic remplissage. This reproducible method may help to prevent the reported complications of remplissage. [Orthopedics. 2017; 40(4):e598-e603.].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safe Zone Technique Improves Suture Placement During Remplissage

This open‐access article is published and distributed under the Creative Commons Attribution ‐ NonCommercial ‐ No Derivatives License (http://creativecommons.org/licenses/by‐nc‐nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article w...

متن کامل

Accuracy of Suture Passage During Arthroscopic Remplissage—What Anatomic Landmarks Can Improve It?

BACKGROUND Recent data suggest that inaccurate suture passage during remplissage may contribute to a loss of external rotation, with the potential to cause posterior shoulder pain because of the proximity to the musculotendinous junction. PURPOSE To evaluate the accuracy of suture passage during remplissage and identify surface landmarks to improve accuracy. STUDY DESIGN Descriptive laborat...

متن کامل

Early Clinical Results of Arthroscopic Remplissages in Patients with Anterior Shoulder Instability with Engaging Hill-Sachs Lesion in Iran

Background:   To assess the outcome of the remplissage arthroscopic surgical method in patients with anterior shoulder dislocation associated with Hill-Sachs lesion.     Methods:   Ten patients with anterior shoulder dislocations and Hill-Sachs lesions were entered into this study and were operated on by the remplissage arthroscopic surgical method. They were followed up 22 months after surgery...

متن کامل

Arthroscopic Bridge Technique for PCL Avulsion: Surgical Technique and Key Points

This study redescribes an arthroscopic bridge technique for repair of avulsion of the posterior cruciate ligament. The procedure is performed step-to-step. In this technique we created two bone tunnels in the anterior aspect of the tibia and inferior medial of the tibia tuberosity and then create suture fixation of the fragment using the suture bridge. The arthroscopic bridge technique was used...

متن کامل

The Tripod-Pulley Technique for Arthroscopic Remplissage in Engaging Hill-Sachs Lesions

Arthroscopic Bankart repair is now a well-established technique for the treatment of shoulder instability. However, failure rates are considerable when significant bony defects are not addressed. Hill-Sachs lesions, present in the vast majority of those with recurrent anterior instability, when of significant dimension and location, may account for some of these failures. The remplissage proced...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 40 4  شماره 

صفحات  -

تاریخ انتشار 2017