Intraprostatic Fiducials Compared with Bony Anatomy and Skin Marks for Image-Guided Radiation Therapy of Prostate Cancer
نویسندگان
چکیده
Purpose Prostate motion occurs during radiotherapy for localized prostate cancer. We evaluated the input of intraprostatic fiducials for image-guided radiation therapy and compared it with bony anatomy and skin marks. Methods Eleven patients were implanted with three fiducial markers in the prostate. Daily sets of orthogonal kV-kV images were compared with digitally reconstructed radiography. Data were recorded for skin marks, bony anatomy, and fiducial markers. The variations were analyzed along three principal axes (left-right: LR, superoinferior: SI, and anteroposterior: AP). Results A total of 2,417 measures were recorded over 38 fractions of radiotherapy (76 Gy). Fiducial marker movements from bony anatomy were ≤ 5 mm for 84.2% (confidence interval: CI 95%±1.5), 91.3% (CI 95%±1.1), and 99.5% (CI 95%±0.4) of the measures along the AP, SI, and LR axes, respectively. Ninety-five percent of the shifts between a fiducial marker and the bony anatomy were < 8 mm in the AP and SI axes, and < 3 mm in the LR axis. Fiducial marker movements from skin marks were ≤ 5 mm for 64.8% (CI 95%±1.9), 79.2% (CI 95%±1.6), and 87.2% (CI 95%±1.3) of the measures along the AP, SI, and LR axes, respectively. Bony anatomy movements from skin marks were ≤ 5 mm for 84% (CI 95%±1.4), 92% (CI 95%±1.1), and 87% (CI 95%±1.3) of the measurements along the AP, SI, and LR axes, respectively. Conclusion Using fiducial markers provides better accuracy of repositioning of the prostate than using bony anatomy and skin marks for image-guided radiotherapy of prostate cancer.
منابع مشابه
The Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography
Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomograph...
متن کاملHealth technology assessment of image-guided radiotherapy (IGRT): A systematic review of current evidence
Background: Image-guided radiotherapy used multiple imaging during the radiation therapy course to improve the precision and accuracy of health care provider's treatment. Objectives: This study aims to assess the safety, effectiveness and economic aspects of image-guided radiation therapy for decision-making about this technology in Iran. Methods: In this study, the most important med...
متن کاملEarly toxicity of moderate hypofractionated volumetric modulated Arc radiotherapy for localized prostate cancer
Background: Based on the radiation biology model of prostate cancer, hypofractionated radiotherapy can improve the treatment outcomes without increasing toxicity. Although hypofractionated radiotherapy is implemented over a short period of time, it is more convenient and cheaper compared with conventional fractionated treatment. The aim of this study was to investigate the early toxicity of mod...
متن کاملUtilization of cone-beam CT for offline evaluation of target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment.
AIM To assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction. BACKGROUND Implementation of IGRT should influence safety margins. Utilization of cone-beam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose d...
متن کاملImage-guided prostate radiotherapy: analysis of inter- fractional setup errors
Introduction: The accuracy of the patient setup and tumor location are major factors that determine the efficacy of radiotherapy treatment planning. In the prostate radiotherapy, reproducibility of the prostate location for each treatment fraction is problematic owing to varying filling of the rectum and bladder. According to this, the aim of this study was to measure the inte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2017