Spatial Resolution of Single-Cell Exocytosis by Microwell-Based Individually Addressable Thin Film Ultramicroelectrode Arrays

نویسندگان

  • Jun Wang
  • Raphaël Trouillon
  • Johan Dunevall
  • Andrew G. Ewing
چکیده

We report the fabrication and characterization of microwell-based individually addressable microelectrode arrays (MEAs) and their application to spatially and temporally resolved detection of neurotransmitter release across a single pheochromocytoma (PC12) cell. The microwell-based MEAs consist of 16 4-μm-width square ultramicroelectrodes, 25 3-μm-width square ultramicroelectrodes, or 36 2-μm-width square ultramicroelectrodes, all inside a 40 × 40 μm square SU-8 microwell. MEAs were fabricated on glass substrates by photolithography, thin film deposition, and reactive ion etching. The ultramicroelectrodes in each MEA are tightly defined in a 30 × 30 μm square area, which is further encased inside the SU-8 microwell. With this method, we demonstrate that these microelectrodes are stable, reproducible, and demonstrate good electrochemical properties using cyclic voltammetry. Effective targeting and culture of a single cell is achieved by combining cell-sized microwell trapping and cell-picking micropipet techniques. The surface of the microelectrodes in the MEA was coated with collagen IV to promote cell adhesion and further single-cell culture, as good adhesion between the cell membrane and the electrode surface is critical for the quality of the measurements. Imaging the spatial distribution of exocytosis at the surface of a single PC12 cell has also been demonstrated with this system. Exocytotic signals have been successfully recorded from eight independent 2-μm-wide ultramicroelectrodes from a single PC12 cell showing that the subcellular heterogeneity in single-cell exocytosis can be precisely analyzed with these microwell-based MEAs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous study of subcellular exocytosis with individually addressable multiple microelectrodes.

We report the application of individually addressable microelectrode arrays (MEAs) to study the heterogeneity of cell exocytosis at the subcellular level. Multiple subcellular-size electrodes are covered by a single PC12 cell for the investigation of subcellular exocytosis. PC12 cells have been seeded and cultured on top of three kinds of MEAs containing 16, 25, or 36 square microelectrodes (4 ...

متن کامل

Investigation of Physical Properties of e-Beam Evaporated CdTe Thin Films for Photovoltaic Application

CdTe thin films with 2.8 µm thickness were deposited by electron beam evaporation method. X-ray diffraction, scanning electron microscopy, UV-Vis-NIR spectroscopy and atomic force microscopy (AFM) were used to characterize the films. The results of AFM analysis revealed that the CdTe films have uniform surface. CdTe thin films were heat-treated by SnCl2 solution. Structural analysis using XRD s...

متن کامل

The Effects of Different Seed Layers and Growth Time on the Quality of ZnO NRs Arrays

ZnO nanorods (NRs) were synthesized using an in situ low-temperature hydrothermal method. In order to investigate the effect of different seed layers on quality of ZnO NRs arrays, alcoholic, alkaline and acidic seed solutions were deposited by spin coating on ITO-glass substrate. Experimental results revealed that the vertically ZnO NRs obtained from monoethanolamine-based seed layer is the...

متن کامل

Bioelectrochemical Imaging with Micro/Nanoelectrode Systems

This paper report a novel approach for bioimaging with two different micro/nanoelectrode systems; i. e., scanning electrochemical microscopy (SECM) and individually addressable microelectrode array. Hybrid SECM systems with shear-force or ion-conductance feedback distance control were applied to high resolution and simultaneous imaging of topography and electrochemical responses of enzymes and ...

متن کامل

Addressable nanowell arrays formed using reversibly sealable hybrid elastomer-metal stencils.

There are two major array formats used in life science research and biomedical analysis. The first is the microwell plate format with millimeter-sized wells each with microliter capacity addressed individually and repeatedly during experiments. The second is the microarray format with micrometer-sized spots that are patterned initially but not addressable individually thereafter. Here, we prese...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 86  شماره 

صفحات  -

تاریخ انتشار 2014